Suscribirse

The role of brachioradialis release during AO type C distal radius fracture fixation - 07/11/17

Doi : 10.1016/j.otsr.2017.06.015 
T. Ma a, b, 1, X. Zheng c, 1, X.-B. He a, K.-J. Guo a,
a Department of orthopaedics, the First school of clinical medicine, Nanjing medical university, no. 101, Longmian avenue, Jiangning District, 211166 Nanjing, Jiangsu, P.R. China 
b Department of orthopaedics, Yi Jishan hospital, Wannan medical college, Wuhu, P.R. China 
c Department of orthopaedics, the Affiliated hospital of Xuzhou medical university, Xuzhou, P.R. China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Open reduction and internal fixation of distal radius fractures often necessitates release of the brachioradialis from the radial styloid. However, whether this common procedure makes the reduction and fixation easier and affects the elbow function has not been fully understood.

Hypothesis

Brachioradialis (BR) release during volar plate fixation for type C distal radius fractures makes internal reduction and fixation easier, and it does not adversely affect wrist or elbow function.

Material and methods

A total of 74 patients treated with 2.4mm volar locking compression column plate (VCP) were analyzed for type C distal radius fractures prospectively. The patients were divided into two groups, group A with BR release and group B without BR release. The two groups were compared in terms of “internal reduction and fixation time” during the operation, wrist and elbow function including the scores of Gartland and Werley (G-W), Patient-related wrist evaluation score (PRWE), Mayo Elbow Performance Score (MEPS), the Disabilities of the arm, shoulder, and hand (DASH) and a Visual analog scale (VAS) for pain at 6 and 12 months postoperatively. The radial inclination angle, palmar tilt angle and ulnar variance were also measured from the radiographs.

Results

According to the follow-up of the 74 patients, no significant differences were observed between the two groups on MEPS, DASH, G-W, PRWE, VAS and radiological outcomes at 6 and 12 months postoperatively. Mean time of reduction and internal fixation was significantly shorter in group A than that in group B.

Conclusion

Release of the BR for type C distal radius fractures facilitated the surgical procedure and did not adversely affect elbow and wrist function.

Level of evidence

II, prospective comparative study.

El texto completo de este artículo está disponible en PDF.

Keywords : Distal radius fracture, Brachioradialis release, Column plate, Open reduction and internal fixation


Esquema


© 2017  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 7

P. 1099-1103 - novembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Clinical and radiological outcomes following radioscapholunate fusion
  • D. Montoya-Faivre, G. Pomares, V. Calafat, F. Dap, G. Dautel
| Artículo siguiente Artículo siguiente
  • Emergency metacarpophalangeal arthroplasty with bone grafting for traumatic joint destruction
  • G. Pomares, V. Calafat, D. Montoya-Faivre, F. Dap, G. Dautel

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.