Suscribirse

Factors affecting peri-implant fracture following locking plate for osteoporotic distal femur fractures - 23/11/17

Doi : 10.1016/j.otsr.2017.08.008 
K.-C. Park a, 1 , S.-J. Lim b, 1 , Y.S. Song c , K.-T. Hwang c,
a Department of orthopaedic surgery, Hanyang university, Guri hospital, 249-1 Gyomoon-dong, 471-701 Guri city, Gyunggi-do, Korea 
b Department of orthopaedic surgery, Samsung medical center, 50 Ilwon-dong, 135-710 Gangnam-gu, Seoul, Korea 
c Department of orthopaedic surgery, Hanyang university hospital, 17 Haengdang-dong, 133-792 Seongdong-gu, Seoul, Korea 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The purpose of this study is to evaluate the outcomes and to analyze the risk factors for the occurrence of peri-implant fracture after treatment of osteoporotic distal femoral fractures using a locking plate.

Hypothesis

Risk factors affecting peri-implant fracture exist after locking plate fixation in osteoporotic distal femur fracture.

Materials and methods

Eighty-nine cases (88 patients) with osteoporotic distal femoral fractures were evaluated between January 2006 and January 2014. The cohort included 13 men and 76 women with a mean age of 70.4 (50–91). Mean duration of follow-up was 47.9 months (12 to 106). All patients with distal femoral fracture were treated with a locking compression plate. Bone mineralized densitometry measurement was obtained from all patients. Risk factors including sex, age, rheumatoid arthritis (RA), taking of bisphosphonate, primary or periprosthetic fracture after total knee arthroplasty (TKA), open or closed fracture, types of the most proximal screw (locking/cortical), and number of proximal screws were analyzed. Complication, union, time to union, and range of motion of knee were also evaluated.

Results

All patients had osteoporosis with the mean BMD of −3.16 (−2.5∼−5.4). The mean range of motion of knee was 126 degrees (90–145). Eighty-four cases (94.4%) showed union, the mean time to union was 14 weeks (10–42). Peri-implant fractures occurred in four patients (4.5%) after bone union at mean 37.5 months (14–62) postoperatively. Eight patients had angular deformities of over 5 degrees. Nonunion was observed in 5 cases and superficial wound infection in 2 cases. There were eight patients with RA, two of whom had suffered a peri-implant fracture. In statistical analysis, rheumatoid arthritis or periprosthetic fracture in TKA patients was a risk factor for peri-implant fracture (P=0.039, 0.019, respectively), and other factors showed no statistical differences.

Conclusions

Treatment using a locking plate showed favorable outcomes in osteoporotic distal femoral fractures. However, peri-implant fracture could occur in patients with RA or periprosthetic fracture after TKA. Therefore, cautious consideration is required for management of osteoporotic distal femur fracture in patients with RA or periprosthetic fracture after TKA. Analysis of more cases will be needed in order to achieve conclusive results.

Level of evidence

Therapeutic study, level IV (retrospective study). See the Guidelines for Authors for a complete description of levels of evidence.

El texto completo de este artículo está disponible en PDF.

Keywords : Distal femoral fracture, Osteoporosis, Peri-implant fracture, Locking plate


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 8

P. 1201-1204 - décembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Reconstructing the chronically disrupted knee extensor mechanism after total knee arthroplasty: Hourglass variant of the original partial allograft technique
  • C. Fiquet, A. Schneider, R. Ballis, E. Servien, P. Neyret, S. Lustig
| Artículo siguiente Artículo siguiente
  • Ankle fusion in hemophilic patients
  • D. Eichler, M. Ehlinger, A. D’Ambrosio, D. Desprez, G. Bierry, P. Adam, F. Bonnomet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.