Volumetric measurement of hepatic tumors: Accuracy of manual contouring using CT with volumetric pathology as the reference method - 28/02/18

Doi : 10.1016/j.diii.2017.11.002 
L.F. Pupulim a, M. Ronot a, c, d, , V. Paradis b, c, d, S. Chemouny e, V. Vilgrain a, c, d
a Department of Radiology, University Hospitals Paris-Nord–Val-de-Seine, AP–HP, Beaujon, 92110 Clichy, France 
b Department of Pathology, University Hospitals Paris-Nord–Val-de-Seine, AP–HP, Beaujon, 92110 Clichy, France 
c University Paris-Diderot, Sorbonne Paris Cité, 75013 Paris, France 
d Inserm U1149, centre de recherche biomédicale Bichat-Beaujon CRB3, 75018 Paris, France 
e Intrasens, 34000 Montpellier, France 

Corresponding author. Radiology department, Beaujon Hospital, 100, boulevard du Général-Leclerc, 92110 Clichy, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purpose of this study was to assess the accuracy of liver tumor volumetry by manual contouring on computed tomography (CT) compared to pathological tumor volume determined from surgical specimen that served as a reference method.

Patients and method

Thirty-eight patients with planned liver surgery and a total of 41 liver tumors were included. There were 24 men and 14 women (mean age: 57 years; range: 32–85 years). Two readers calculated tumor volume by manual contouring on axial CT images. The reference tumor volume was calculated by manual contouring with dedicated software applied to the liver specimen slice. CT and pathology volumes were compared and the percentage of error (PE%) was calculated. Intraobserver and interobserver variabilities were calculated using Bland and Altman plots, and intraclass correlation coefficients (ICC).

Results

A strong correlation was found between CT tumor volumes and pathology tumor volumes (r=0.994; P<0.001 for both readers). The mean (±SD) and median (range) PE% were 19%±12% and 16% (1%, +42%) and 19%±15% and 17% (0%, +55%) for readers 1 and 2, respectively. Readers 1 and 2 significantly overestimated tumor volume (i.e., PE%>40%) in 3 (7%) and 2 (5%) tumors on CT, respectively. Tumor volume was not significantly underestimated in any of the patients (i.e. PE%>33%). Tumor size, CT attenuation, time between imaging and surgery, contours and margin definition did not influence the results of PE% values (all P values>0.05 for both readers). The bias and limits of agreement between the two readers were +4.6% and (−24%, +33%) with an ICC of 0.997.

Conclusion

There was a strong correlation between tumor volume measured on CT and that assessed with surgical specimen. Tumor size, visibility of contours and tumor margins and the time between CT and surgery did not influence the results.

El texto completo de este artículo está disponible en PDF.

Keywords : Liver volumetry, Tissue segmentation, Semiautomatic method, Liver


Esquema


© 2017  Editions françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 2

P. 83-89 - février 2018 Regresar al número
Artículo precedente Artículo precedente
  • Measurement variability of liver metastases from neuroendocrine tumors on different magnetic resonance imaging sequences
  • T. Lestra, L. Kanagaratnam, S. Mulé, A. Janvier, H. Brixi, G. Cadiot, A. Dohan, C. Hoeffel
| Artículo siguiente Artículo siguiente
  • CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses
  • T. Iguchi, T. Hiraki, Y. Matsui, H. Fujiwara, J. Sakurai, Y. Masaoka, M. Uka, T. Tanaka, H. Gobara, S. Kanazawa

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.