Suscribirse

Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach - 24/04/18

Doi : 10.1016/j.otsr.2017.11.023 
Y.K. Lee a, 1, J.W. Kim a, 1, T.Y. Kim b, c, , Y.C. Ha d, K.H. Koo a
a Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, 166 Gumi-ro, Bundang-gu, Seongnam 463-707 South Korea 
b Hallym University Sacred Heart Hospital, Department of Orthopaedic Surgery, 896 Pyeongchon-dong, Dongan-gu, Anyang 431-070, South Korea 
c Konkuk University Medical Center, Department of Orthopaedic Surgery, School of Medicine, Konkuk University, Seoul 05030, South Korea 
d Chung-Ang University, College of Medicine, Department of Orthopaedic Surgery, 224-1 Heukseok-dong, Dongjak-gu, Seoul 156-755, South Korea 

Corresponding author at: Konkuk University Medical Center, Department of Orthopaedic Surgery, School of Medicine, Konkuk University, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, 05030, South Korea.Konkuk University Medical Center, Department of Orthopaedic Surgery, School of Medicine, Konkuk University, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, 05030, South Korea.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Intra-operative estimation of stem anteversion in total hip arthroplasty (THA) using postero-lateral approach is made by the surgeon's visual assessment, using the tibia as a guide, with the assumption that tibial axis is vertical to the trans-epicondylar axis. However, the accuracy of the intra-operative estimation has rarely been verified with postoperative CT-scans, with controversies regarding these measurements particularly in case of knee osteoarthritis. Therefore we performed a prospective study to: (1) determine the accuracy of the intra-operative measurement and (2) investigate factors affecting the discrepancy between the surgeon's estimation and the real stem anteversion.

Hypothesis

Intra-operative estimation of stem anteversion correlated with the real stem anteversion on CT-scan.

Patients and methods

Sixty-seven THAs using cementless straight stems (65 patients) without ipsilateral total knee arthroplasty were prospectively evaluated to compare the intra-operative measurement of stem anteversion with the real stem anteversion on computed tomography (CT) scans. There were 33 men and 34 women with a mean age of 59.7years (range, 27–84years) at the time of surgery. Age, tibia plateau angle, native femoral anteversion, femoro-tibial angle, body mass index, operative site, gender, coronal and sagittal tilt of the stem, stem type, ipsilateral knee osteoarthritis, and preoperative diagnosis were analyzed to evaluate the factors affecting the discrepancy between the intra-operative and CT measurements.

Results

The intra-operative estimation (mean, 21.5°±8.5°; range, 5.0°–39.0°) was greater than the CT measurement (mean, 19.5°±8.7°; range, 4.5°–38.5°) by 2.0°. The mean absolute value of discrepancy was 4.5°. The correlation coefficient between intra-operative and CT measurements was 0.837. The femoro-tibial angle was associated with the discrepancy between the two measurements. In the presence of genu varum deformity, the intra-operative measurement underestimated the stem anteversion.

Discussion

Although intra-operative estimation of stem anteversion was slightly greater than the real stem anteversion, there was an excellent correlation between the two. The femoro-tibial angle should be considered to optimize the stem anteversion during cementless THA using postero-lateral approach.

Level of evidence

Level III, prospective case control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Intra-operative estimation, Anteversion, Femoro-tibial angle, Cementless stem, Total hip arthroplasty, Postero-lateral approach


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 3

P. 341-346 - mai 2018 Regresar al número
Artículo precedente Artículo precedente
  • Complications with cement spacers in 2-stage treatment of periprosthetic joint infection on total hip replacement
  • R. Erivan, T. Lecointe, G. Villatte, A. Mulliez, S. Descamps, S. Boisgard
| Artículo siguiente Artículo siguiente
  • Is anatomic acetabular orientation related to pelvic morphology? CT analysis of 150 healthy pelvises
  • P. Sautet, H. Giorgi, P. Chabrand, P. Tropiano, J.-N. Argenson, S. Parratte, B. Blondel

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.