Suscribirse

Opening-wedge high tibial osteotomy performed with locking plate fixation (TomoFix) and early weight-bearing but without filling the defect. A concise follow-up note of 48 cases at 10 years’ follow-up - 11/06/18

Doi : 10.1016/j.otsr.2017.12.021 
M. Darees a, , S. Putman a, b, T. Brosset c, T. Roumazeille a, G. Pasquier a, b, H. Migaud a, b
a Services d’Orthopédie C et D, Hôpital Salengro, place de Verdun, 59000 Lille, France 
b Université de Lille, Hauts de France, 59000 Lille, France 
c Centre chirurgical Saint-Roch, route de Gordes, 84300 Cavaillon, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Use of a locking plate during medial opening high tibial osteotomy (HTO) eliminates the need to fill the defect and its associated complications. It also allows early weight-bearing. Since long-term data with this type of construct are rare, we wanted to report the outcomes of a 51-patient cohort evaluated after a mean follow-up of 10.2years. The goals were to determine (1) the HTO survival and whether the correction was maintained between 2 and 10years later, (2) the stability of the functional outcomes, (3) the complication rate related to use of locking plates.

Hypothesis

The correction following medial opening HTO with a Tomofix™ plate without void filling is maintained after 10years’ follow-up.

Material and methods

Fifty-one patients ranging from 37 to 72years of age at the time of surgery between 2003 and 2005 underwent a medial opening HTO that was stabilized with a Tomofix™ locking plate (Synthes, Oberdorf, Switzerland) without void filling. Forty-eight patients were reviewed between March and September 2014; 1 patient had died and 2 were lost to follow-up.

Results

The mean HKA angle went from 172±3.18° (165–178°) preoperatively to 181±1.18° (176–185°) postoperatively, to 181±1.60° (176–185°) at 2years, and 180.8±2.4° (175–184°) at 10years’ follow-up. This equates to a loss of correction of 0.71±1.9° (0–6°) (p=0.02) between 2 and 10years after the surgery. Five patients underwent total knee arthroplasty (TKA), thus the 10-year survival of the HTO procedure was 88% (95% CI: 81–98%). If the five TKA procedures are excluded, the mean IKS knee score went from 90±7.4 (66–98) at 2years’ follow-up to 77±15.3 (43–97) at 10years (p>0.05). There were four complications in all (8%), of which three occurred within 2years (2 cases of nonunion and 1 surgical site infection) and one occurred later (infection after 118months that resolved once the hardware was removed and the patient given appropriate antibiotics). There were no complications related to the five subsequent TKA procedure and no bone grafting was required.

Discussion

There was a small (less than 1 degree) but statistically significant loss of correction and non-significant deterioration in the functional outcomes. Conversely, the complication rate did not increase over time, despite the lack of void filling, particularly in patients who subsequently underwent TKA. The 10-year survival was similar to other HTO procedures. This locking plate construct without void filling is reliable after 10years.

Level of evidence

Level IV, prospective study without control group.

El texto completo de este artículo está disponible en PDF.

Keywords : Knee, Knee osteoarthritis, High tibial osteotomy, Open wedge, Locking plate


Esquema


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 4

P. 477-480 - juin 2018 Regresar al número
Artículo precedente Artículo precedente
  • Opening-wedge high tibial osteotomy without bone grafting in severe varus osteoarthritic knee. Rate and risk factors of non-union in 41 cases
  • R. Siboni, P. Beaufils, P. Boisrenoult, C. Steltzlen, N. Pujol
| Artículo siguiente Artículo siguiente
  • Is distal femoral torsion the same in both of a patient's legs? Morphometric CT study
  • J.-S. Beranger, D. Dujardin, J.-F. Taburet, P. Boisrenoult, C. Steltzlen, P. Beaufils, N. Pujol

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.