Suscribirse

Is distal femoral torsion the same in both of a patient's legs? Morphometric CT study - 11/06/18

Doi : 10.1016/j.otsr.2018.02.014 
J.-S. Beranger , D. Dujardin, J.-F. Taburet, P. Boisrenoult, C. Steltzlen, P. Beaufils, N. Pujol
 Service d’orthopédie traumatologie, centre hospitalier de Versailles, hôpital André-Mignot, 78150 Le Chesnay, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The rotational position of the femoral component is a primary driver of success in total knee arthroplasty. However, distal femoral torsion (DFT) varies greatly between individuals. Measuring DFT preoperatively by CT in combination with computer-assisted surgery can significantly improve the rotational positioning of the femoral component. However, a preoperative CT scan is costly and exposes the patient to radiation. These are doubled when the patient is undergoing bilateral arthroplasty. The aim of this study was to determine the DFT in both knees of a patient undergoing bilateral arthroplasty. We hypothesized that DFT was symmetric between a patient's two knees and was independent of frontal alignment.

Material and methods

In this retrospective study of TKA cases performed between December 2008 and March 2015, 82 patients (mean age 73years) who underwent two-stage bilateral TKA (164 knees) were included. A preoperative CT scan of each knee was performed to measure the DFT using the surgical posterior condylar angle (PCA) described by Yoshioka. Two observers performed the measurements twice each, to allow calculation of the intraclass and interclass correlation coefficients.

Results

The mean PCA was 5.4° (±1.48) in the right knee and 5.4° (±1.45) in the left knee, with a left/right difference ranging from 0 to 2.2° (p=0.8). In the entire cohort, 84.6% of patients had a left/right difference of less than 1°. We found no significant differences in DFT in knees with large or small frontal deformity (deformity<10°, p=0.7; deformity>10°, p=0.5) or the presence of varus or valgus (p=0.9). The intraclass correlation coefficient was excellent (94%) and the interclass correlation coefficient was moderate to good (60% for left knees, 53% for right knees).

Discussion

Based on CT scan measurements, the DFT in both knees of an arthritic patient is comparable and this measurement is reproducible. This means that a single, unilateral preoperative CT scan is sufficient for planning purposes.

Level of evidence

IV (retrospective cohort study).

El texto completo de este artículo está disponible en PDF.

Keywords : Total knee arthroplasty, Distal femoral torsion, Morphometry, Symmetry


Esquema


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 4

P. 481-484 - juin 2018 Regresar al número
Artículo precedente Artículo precedente
  • Opening-wedge high tibial osteotomy performed with locking plate fixation (TomoFix) and early weight-bearing but without filling the defect. A concise follow-up note of 48 cases at 10 years’ follow-up
  • M. Darees, S. Putman, T. Brosset, T. Roumazeille, G. Pasquier, H. Migaud
| Artículo siguiente Artículo siguiente
  • Medial meniscus posterior root tear induces pathological posterior extrusion of the meniscus in the knee-flexed position: An open magnetic resonance imaging analysis
  • S. Masuda, T. Furumatsu, Y. Okazaki, Y. Kodama, T. Hino, Y. Kamatsuki, S. Miyazawa, T. Ozaki

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.