Suscribirse

Anterior cruciate ligament reconstruction with the Tape Locking Screw (TLS) and a short hamstring graft: Clinical evaluation of 61 cases with a minimum 12 months’ follow-up - 22/08/18

Doi : 10.1016/j.otsr.2018.03.016 
Benoît Orfeuvre , Régis Pailhé, Loïc Sigwalt, Brice Rubens Duval, Gabriel Lateur, Stéphane Plaweski, Dominique Saragaglia
 Service de chirurgie orthopédique et de traumatologie du sport, hôpital Sud, CHU de Grenoble-Alpes, 38130 Échirolles, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The Tape Locking Screw (TLS®) technique for anterior cruciate ligament (ACL) reconstruction has the advantages of using only one hamstring tendon (semitendinosus) by preparing a short graft secured with screws and braided strips. The theoretical pitfall of this technique is that the graft length is determined arbitrarily. Thus, if the blind tunnels are not long enough, it will be impossible to tension the graft properly upon fixation. The primary objective of this study was to determine the postoperative side-to-side difference in knee laxity. We hypothesized that ACL reconstruction with the TLS(R) system would result in 3mm or less side-to-side difference in knee laxity.

Material and Methods

This was a prospective single-center, single-surgeon study performed on patients operated between December 2014 and June 2016 who had a minimum 12 months’ follow-up. The pre- and post-operative side-to-side difference in knee laxity was measured with a KT-1000 arthrometer. Secondary outcomes were the pre- and post-operative IKDC, Lysholm and Tegner functional scores.

Results

Sixty-one patients were included: 49 men (80%) and 12 women (20%). The average age was 31.6±13.7 years. The average follow-up was 19.3±6.3 months. The average side-to-side difference in laxity went from 6.5mm (min 3; max 12) preoperatively to −0.1mm postoperatively (min −5, max 4) (p<0.01). The average IKDC went from 39.7±12 preoperatively to 94.1±11.2 postoperatively (p<0.005), the average Lysholm score went from 41±12.9 to 95.5±9.8 (p<0.005), and the average Tegner score went from 6.3±1.5 to 4.3±1.4 (p<0.005). Patients were able to return to sports an average of 6.1 months after surgery. In terms of complications, 4.9% of patients developed a cyclops lesion and required surgical revision.

Discussion

This study found very good reduction in postoperative laxity after a minimum 12 months’ follow-up when ACL reconstruction is performed with the TLS® technique.

Level of evidence

IV, prospective cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Anterior cruciate ligament, Ligament reconstruction, Knee laxity, Tape Locking Screw (TLS®), ST4, Short graft


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 5

P. 701-705 - septembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Treatment of large deep osteochondritis lesions of the knee by autologous matrix-induced chondrogenesis (AMIC): Preliminary results in 13 patients
  • Pierre Bertho, Adrien Pauvert, Thomas Pouderoux, Henri Robert, Orthopaedics and Traumatology Society of Western France (SOO) d
| Artículo siguiente Artículo siguiente
  • Does medial collateral ligament pie-crusting induce residual laxity in arthroscopic management of medial meniscus tears? A prospective study of 40 cases
  • Adrien Lons, Florian Boureau, Elodie Drumez, Gilles Pasquier, Sophie Putman

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.