Suscribirse

Dynamic contrast-enhanced MR imaging of the rectum: Correlations between single-section and whole-tumor histogram analyses - 17/09/18

Doi : 10.1016/j.diii.2018.04.009 
M.H. Choi a, b, S.N. Oh a, b, , G.E. Park a, D.-M. Yeo c, S.E. Jung a, b
a Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea 
b Cancer Research Institute, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea 
c Department of Radiology, Daejeon St Mary's Hospital, College of Medicine, The Catholic University of Korea, Daejeon, Republic of Korea 

Corresponding author. Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222, Banpo-daero, Seocho-gu, Seoul 06591, Korea.Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222, Banpo-daero, Seocho-gu, Seoul 06591, Korea.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To evaluate the interobserver and intermethod correlations of histogram metrics of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters acquired by multiple readers using the single-section and whole-tumor volume methods.

Materials and methods

Four DCE parameters (Ktrans, Kep, Ve , Vp) were evaluated in 45 patients (31 men and 14 women; mean age, 61±11 years [range, 29–83 years]) with locally advanced rectal cancer using pre-chemoradiotherapy (CRT) MRI. Ten histogram metrics were extracted using two methods of lesion selection performed by three radiologists: the whole-tumor volume method for the whole tumor on axial section-by-section images and the single-section method for the entire area of the tumor on one axial image. The interobserver and intermethod correlations were evaluated using the intraclass correlation coefficients (ICCs).

Results

The ICCs showed excellent interobserver and intermethod correlations in most of histogram metrics of the DCE parameters. The ICCs among the three readers were > 0.7 (P<0.001) for all histogram metrics, except for the minimum and maximum. The intermethod correlations for most of the histogram metrics were excellent for each radiologist, regardless of the differences in the radiologists’ experience.

Conclusion

The interobserver and intermethod correlations for most of the histogram metrics of the DCE parameters are excellent in rectal cancer. Therefore, the single-section method may be a potential alternative to the whole-tumor volume method using pre-CRT MRI, despite the fact that the high agreement between the two methods cannot be extrapolated to post-CRT MRI.

El texto completo de este artículo está disponible en PDF.

Keywords : Dynamic contrast-enhanced MRI, Rectal cancer, Histogram, Interobserver variability, Quantitative measurement


Esquema


© 2018  Soci showét showé françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 9

P. 537-545 - septembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Transarterial chemoembolization (TACE) in the management of hepatocellular carcinoma: Results of a French national survey on current practices
  • A. Fohlen, J.P. Tasu, H. Kobeiter, J.M. Bartoli, J.P. Pelage, B. Guiu
| Artículo siguiente Artículo siguiente
  • Push versus pull gastrostomy in cancer patients: A single center retrospective analysis of complications and technical success rates
  • B.M. Currie, G.I. Getrajdman, A.M. Covey, W. Alago, Jr, J.P. Erinjeri, M. Maybody, F.E. Boas

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.