Suscribirse

Medial malleolus fractures: A biomechanical comparison of tension band wiring fixation methods - 23/11/18

Doi : 10.1016/j.otsr.2018.06.011 
Esat Uygur a, , Oguz Poyanli a, İbrahim Mutlu b, Talip Çelik b, Fuat Akpinar a
a Orthopaedics and Traumatology department, İstanbul Medeniyet University Göztepe Training and Research Hospital, Kadıköy, Turkey 
b Technology Faculty, Biomedical Engineering, Kocaeli University, Kocaeli, Turkey 

Corresponding author. İstanbul Medeniyet University, Orthopaedics and Traumatology, Egitim Mah, Doktor Erkin Cad, Göztepe Egitim ve Arastirma Hastanesi, 34732 Kadıköy, Turkey.İstanbul Medeniyet University, Orthopaedics and Traumatology, Egitim MahDoktor Erkin Cad, Göztepe Egitim ve Arastirma HastanesiKadıköy34732Turkey

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

This study compared the biomechanical properties of three different fixation methods of tension band wirings, used in the treatment of medial malleolus fractures. The first method used an innovative “handmade bent pin” for cerclage fixation. The second method used a U-shaped K-wire to attach the cerclage to the medial tibial cortex. These two novel fixation techniques were compared with the traditional tension band wiring technique which is fixated to the bone by a screw.

Hypothesis

Novel fixation techniques of tension band wiring provide stable fixation.

Material and methods

In this study 27 artificial bone models, which medial malleolus fractures were simulated on, were used. Using an electromechanical test device, the force required to pull out each implant was assessed and compared.

Results

This study found that; while handmade bent pinning resulted averagely 840.25N (range: 647–1066±118.72) and U-shaped K-wire fixation was 381.71N (range: 176–651±150.2) pull out strength, traditional tension band wiring indicated 871.33N (range: 549–1008±137.74) pull out strength.

Discussion

Handmade bent pinning method provide similar results with traditional tension band wiring. Therefore, in suitable cases, it may be an acceptable alternative to traditional tension band wiring techniques when treating malleolar fractures. Although the outcomes of U-shaped K-wire fixation indicated lower than other two groups, the outcomes were comparable with the literature. So while performing tension band wiring, both handmade fixation systems may be used in certain cases. For Orthopaedic surgeons, it is better to know and think about these alternative handmade pinning systems created from simple K-wires during the surgery if needed.

Level of evidence

IV, Biomechanical trial.

El texto completo de este artículo está disponible en PDF.

Keywords : Medial malleolus fractures, Tension bad wiring, Cerclage wiring


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 8

P. 1259-1263 - décembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Outcomes of distal humerus fractures: What are we measuring?
  • Ali Zarezadeh, Kelly Mamelson, W. Christian Thomas, Bradley S. Schoch, Thomas W. Wright, Joseph J. King
| Artículo siguiente Artículo siguiente
  • Impact of setting up a bone and joint infection referral center on arthroscopic treatment of septic arthritis of the knee and shoulder: Retrospective study
  • Marion Besnard, Damien Babusiaux, Pascal Garaud, Philippe Rosset, Louis Bernard, Louis-Romé Le Nail, Julien Berhouet, Orthopedics and Traumatology Society of Western France (SOO) c

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.