Suscribirse

ANGIOPLASTY AND STENTING OF THE CERVICAL CAROTID BIFURCATION UNDER FILTER PROTECTION: A PROSPECTIVE STUDY IN A SERIES OF 53 PATIENTS - 21/03/08

Doi : JNR-03-2005-32-2-0150-9861-101019-200502222 

G. Bonaldi [1 et 2],

L. Aiazzi [3],

F. Baruzzi [2],

F. Biroli [4],

A. Facchinetti [2],

P. Fachinetti [5],

A. Lunghi [1],

F. Terraneo [3]

Ver las filiaciones

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Angioplastie et stenting de la bifurcation carotide cervicale avec filtre de protection : étude prospective de 53 patients

Le but de ce travail est d’évaluer la tolérance, la fiabilité, la facilité d’utilisation et l’intérêt des filtres de protection pendant l’angioplastie et le « stenting » des sténoses de la bifurcation carotide. Sur une période de 42 mois, 53 patients porteurs d’une sténose de la bifurcation carotide ont été traités par angioplastie et/ou « stenting » en utilisant des filtres de protection cérébrale de différents types. Les sténoses étaient d’origine athéroscléreuse (n = 48), post-chirurgicale (n = 4) et post-radiothérapique (n = 1). Les résultats anatomiques étaient dans tous les cas satisfaisants, avec une restauration satisfaisante du diamètre artériel. Il y eut trois cas d’accident cerébral majeur (5,6 %) et un cas mineur (1,9 %). Deux de ces accidents (un majeur et un mineur) sont survenus dans les heures suivant le traitement et correspondaient à un syndrome d’hyperperfusion hémorragique. Une hémiparésie avec dysphasie, survenue 2 jours après le traitement, était liée à un ethrombose subaiguë avec occlusion du stent. Un patient présenta au cours des deux semaines qui suivirent le traitement, trois épisodes de cécité monoculaire homolatéraux à l’endoprothèse. En conclusion, dans notre pratique, la mise en place de filtres de protection cérébrale ajoute quelques minutes à la durée totale du traitement ; des dissections de la paroi artérielle ou thrombi intraluminaux n’ont jamais été observés ; les spasmes distaux de l’artère carotide ont toujours été résolutifs. Le contenu des filtres a été étudié ; du matériel de plaque n’a été observé qu’une seule fois (présence probablement liée à notre technique initiale de stenting sans prédilatation). La principale limite technique est la survenue d’une coagulation au sein du filtre, observée dans 16 cas, responsable d’une occlusion de la membrane du filtre et d’un ralentissement ou d’un arrêt de la circulation. Un tel événement est prévenu par une anticoagulation plus importante qui pourrait être à l’origine de deux infarctus hémorragiques. De plus nous avons observé deux autres complications majeures ce qui porte le taux de complications dans cette série à 7,5 %. À notre avis, la tolérance des filtres n’est pas aujourd’hui démontrée et de grandes précautions sont nécessaires lors de leur utilisation.

The aim of this study is to assess safety, reliability, ease of use and usefulness of filter protection devices d uring angioplasty and stenting of stenotic lesions of the cervical carotid bifurcation. Over a period of 42 months, 53 patients harboring a cervical carotid bifurcation stenotic lesion were treated, by angioplasty and/or stenting using filter protection devices of different kinds. The stenosis was atherosclerotic in 48 cases, post-surgical in four and post-radiation in one case. In all cases, the treatment was successful, with good restoration of the luminal diameter. There were three major strokes (5.6%) and one minor stroke (1.9%). Two of these (one major, one minor) occurred a few hours after the stenting procedure and both seemed by all evidence due to a hemorrhagic hyperperfusion syndrome. One hemiparesis and dysphasia occurred two days after the procedure, secondary to subacute thrombosis with occlusion of the stent. One patient complained of three episodes of decrease in visual acuity of the eye ipsilateral to the stenting in the two weeks following treatment. In conclusion, in our experience, use of the devices adds only few minutes to the procedure time; direct lesions of the arterial wall, such as dissections or intraluminal thrombi, related to the use of filters were never observed, and spasm of the distal I.C.A. also proved rapidly regressive. The content of all filters, if any, was histologically examined, but plaque material was found only in one case, probably owing to our primary stenting technique without use of pre-dilation. The major technical drawback is in-filter coagulation, which occurred in 16 cases, occluding the membrane of the filter and thus slowing or blocking intracranial flow. Such an event can be counteracted by a more aggressive anti-coagulation protocol, which could, however, be responsible for the two complications with hemorrhagic brain infarction. Furthermore, we observed two other major neurological events, which bring the incidence of neurological complications in this series as high as 7.5%. Therefore, it is our opinion that safety of filters is not yet proven, and consequently great care must be taken in their use.


Mots clés : angioplastie , artère carotide , endoprothèse

Keywords: angioplasty , carotid artery disease , stents


Esquema



© 2005 Elsevier Masson SAS. Tous droits réservés.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 32 - N° 2

P. 109-117 - mars 2005 Regresar al número
Artículo precedente Artículo precedente
  • TRAITEMENT ENDOVASCULAIRE DES ANÉVRYSMES NON ROMPUS DE L’ARTÈRE CÉRÉBRALE MOYENNE
  • J.R. Vanzin, C. Mounayer, M. Piotin, L. Spelle, H. Boissonnet, J. Moret
| Artículo siguiente Artículo siguiente
  • RELATION QUANTITATIVE DES MODIFICATIONS DE LA DIFFUSION ET DE LA PERFUSION AU SEIN DU PARENCHYME CÉRÉBRAL AU COURS DE L’ACCIDENT ISCHÉMIQUE AIGU
  • M. Hamon, R.M. Marié, P. Clochon, O. Coskun, J.M. Constans, F. Viader, P. Courthéoux, J.C. Baron

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.