Suscribirse

The ability of magnetic resonance black blood vessel wall imaging to evaluate blunt cerebrovascular injury following acute trauma - 11/02/19

Doi : 10.1016/j.neurad.2019.01.091 
Justin E. Vranic a, , Thien J. Huynh a, Peter Fata a, Jason Barber b, Robert H. Bonow b, Michael R. Levitt a, b, c, d, Nancy Temkin b, Ryan Morton b, Cory Kelly b, d, Dean K. Shibata a, Mahmud Mossa-Basha a
a University of Washington Department of Radiology, United States 
b University of Washington Department of Neurological Surgery, Seattle, WA, United States 
c University of Washington Department of Mechanical Engineering, Seattle, WA, United States 
d University of Washington Stroke and Applied Neuroscience Center, Seattle, WA, United States 

Corresponding author. 325 9th Ave, Seattle WA 98104, United States.325 9th AveSeattle WA 98104United States
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Monday 11 February 2019
This article has been published in an issue click here to access

Abstract

Background and purpose

Blunt cerebrovascular injury (BCVI) is associated with a significant risk of ischemic stroke when left untreated. Cross-sectional imaging is vital to early BCVI diagnosis and treatment; however, conventional luminal vessel imaging is limited in its ability to evaluate for vessel wall pathology. The purpose of this study is to evaluate the ability of vessel wall magnetic resonance imaging (VWI) to detect and evaluate BCVI in acutely injured trauma patients relative to neck computed tomographic angiography (CTA).

Materials and methods

Trauma patients with suspected BCVI on initial neck CTA were prospectively recruited for VWI evaluation. Two neuroradiologists blinded to patient clinical history and CTA findings evaluated each artery independently on VWI and noted the presence and grade of BCVI. These results were subsequently compared to neck CTA findings relative to expert clinical consensus review. Interrater reliability of VWI for detecting BCVI was evaluated using a weighted Cohen κ-statistic.

Results

Ten trauma patients (40 cervical arteries) were prospectively evaluated using both CTA and VWI. Out of 18 vascular lesions identified as suspicious for BCVI on CTA, six lesions were determined to represent true BCVI by expert consensus review. There was almost perfect agreement between VWI and expert consensus regarding the presence and grade of BCVI (κ=0.82). This agreement increased when considering only low grade BCVI. There was only fair agreement between CTA and expert clinical consensus (κ=0.36). This agreement decreased when considering only low grade BCVI.

Conclusions

VWI can potentially accurately identify and evaluate BCVI in acutely injured trauma patients with excellent inter-rater reliability.

El texto completo de este artículo está disponible en PDF.

Keywords : Vessel-wall imaging, Black-blood, Blunt cerebrovascular injury, Vascular trauma

Abbreviations : BCVI, VWI, PD, SPACE, TCD


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.