Early Changes of Myocardial Function After Transcatheter Aortic Valve Implantation Using Multilayer Strain Speckle Tracking Echocardiography - 26/02/19

Doi : 10.1016/j.amjcard.2018.12.008 
Kenji Shiino, MD, PhD a, b, Akira Yamada, MD, PhD a, b, Gregory M. Scalia, MBBS c, d, Anthony Putrino, MBBS c, d, Robert Chamberlain, BSc c, d, Karl Poon, MBBS c, d, Darren L. Walters, MBBS c, d, Jonathan Chan, MBBS, PhD a, c,
a School of Medicine and Menzies Health Institute Queensland, Griffith University, Gold Coast, Australia 
b Department of Cardiology, Fujita-Health University, Nagoya, Japan 
c Department of Cardiology, The Prince Charles Hospital, Brisbane, Australia 
d School of Medicine, University of Queensland, Brisbane, Australia 

Corresponding author: Tel: +61-7-31394000; fax: +61-7-55311834.

Resumen

Transcatheter aortic valve implantation (TAVI) is an effective therapeutic option for severe symptomatic aortic valve stenosis (AS) with intermediate or high surgical risk. The purpose of this study was to examine the effects of TAVI on left ventricular (LV) mechanics using multilayer global longitudinal strain (GLS) by 2D speckle-tracking echocardiography. A total of 119 patients (mean age 83 ± 7.0 years, male 54%) with severe symptomatic AS and normal LV ejection fraction (LVEF) underwent echocardiography at baseline and 1 month after TAVI. Global longitudinal strain was measured from the endocardial layer (GLSendo), mid-ventricular layer (GLSmyo), epicardial layer (GLSepi) and full thickness of myocardium (GLSwhole). There was significant improvement in all 3 layers of GLS after TAVI compared with baseline, but there was no significant change in LVEF. The relative % increment in GLS in each layer strain were 11.2 ± 23.4% (GLSendo), 13.4 ± 33.0% (GLSmyo) and 18.0 ± 46.6% (GLSepi) with significant difference between GLSendo and GLSepi (p < 0.05). In conclusion, multilayer GLS is more sensitive than conventional LVEF to detect early improvement in LV systolic function after TAVI in patients with severe AS. There is a disproportional improvement in different layers with least improvement in the endocardium. Multilayer strain analysis may provide new insights into understanding mechanics of AS.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2018  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 123 - N° 6

P. 956-960 - mars 2019 Regresar al número
Artículo precedente Artículo precedente
  • Impact of Coronary Revascularization in Patients Who Underwent Transcatheter Aortic Valve Implantation
  • Diego López Otero, Alejandro Ávila-Carrillo, Rocío González Ferreiro, Adrián Cid Menéndez, Diego Iglesias Álvarez, Leyre Álvarez Rodríguez, Pablo Antúnez Muiños, Belén Cid Álvarez, Xoan Carlos Sanmartín Pena, Fernando Gómez Pérez, Alfredo Redondo Diéguez, Ignacio Cruz-González, Ramiro Trillo Nouche, José Ramón González-Juanatey
| Artículo siguiente Artículo siguiente
  • Relation of Clinical Presentation of Aortic Stenosis and Survival Following Transcatheter Aortic Valve Implantation
  • Jeremy Ben-Shoshan, David Zahler, Gilad Margolis, Yaron Arbel, Maayan Konigstein, Ehud Chorin, Arie Steinvil, Gad Keren, Shmuel Banai, Ariel Finkelstein

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.