Suscribirse

Improved detection and characterization of arterial occlusion in acute ischemic stroke using contrast enhanced MRA - 29/03/19

Doi : 10.1016/j.neurad.2019.02.011 
Sarah Dhundass a, b, Julien Savatovsky a, Loïc Duron a, R. Fahed c, Simon Escalard c, Michael Obadia d, Kevin Zuber e, Marie Astrid Metten e, Mehdi Mejdoubi e, Raphaël Blanc c, Jean-Claude Sadik a, Adrien Collin a, Augustin Lecler a,
a Department of Neuroradiology, Fondation Ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France 
b Department of Neuroradiology,University Hospital of Martinique, Fort-de-France, Martinique, France 
c Department of Interventional Neuroradiology, Fondation Ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France 
d Department of Neurology, Fondation Ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France 
e Department of Clinical Research, Fondation Ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France 

Corresponding author.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Friday 29 March 2019
This article has been published in an issue click here to access

Abstract

Background and purpose

To compare the accuracy and utility of contrast enhanced magnetic resonance angiography (MRA) (CEMRA) to Time of Flight MRA (TOF MRA) during detection and evaluation of occlusions on patients diagnosed with acute ischemic stroke (AIS).

Methods

This single-center study was approved by our local institutional research ethics board. From August 2014 to July 2016, 131 consecutive adult patients with confirmed AIS were included. Detection of an arterial occlusion and its characterization were evaluated independently with CEMRA or TOF MRA by two blinded neuroradiologists, then by consensus using all available MR sequences. A Cohen's Kappa coefficient (κ) and intra-class correlation coefficients (ICC) were used to compare the two techniques.

Results

There was substantial concordance in the detection of arterial occlusion between CEMRA and TOF MRA (κ = 0.75). TOF MRA was more likely to show an arterial occlusion than CEMRA (63 versus 52 patients respectively). There were 13 and 1 false positive arterial occlusion with TOF MRA and CEMRA respectively, and 1 false negative with TOF MRA. There was excellent concordance between the location of arterial occlusions and CEMRA and TOF MRA [κ = 0.89 (0.72–0.97)]. CEMRA was significantly more likely to allow measurement of the thrombus than was TOF MRA [38 (75%) versus 14 (22%)] (P < 0.0001).

Conclusions

Our study showed that CEMRA imaging detected arterial occlusions better than TOF MRA in AIS patients and more precisely such that thrombus length and location could be known, which improves the patient's management and care.

El texto completo de este artículo está disponible en PDF.

Keywords : Stroke, Arterial occlusion, CEMRA

Abbreviations : CEMRA, TOF MRA, EVT, AIS


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.