Suscribirse

Superior capsular reconstruction for irreparable supraspinatus tendon tears using the long head of biceps: A biomechanical study on cadavers - 31/03/19

Doi : 10.1016/j.otsr.2018.10.023 
Fucai Han a, , Chee Hoe Kong b, Muhammad Yaser Hasan b, Amit K. Ramruttun c, V. Prem Kumar b, c
a Department of Orthopaedic Surgery, Ng Teng Fong General Hospital (National University Health Service Group), National University Health System, 1 Jurong East Street 21, 609606 Singapore, Singapore 
b Department of Orthopaedic Surgery, University Orthopaedics, Hand & Reconstructive Microsurgery Cluster, National University Hospital, National University Health System, Singapore, Singapore 
c Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The superior articular capsule complements the rotator cuff's function in shoulder stability. With irreparable rotator cuff tears, superior capsular reconstruction (SCR) improves dynamic glenohumeral (GH) joint kinematics. We present a novel method of SCR in cadaveric shoulders using the long head of bicep (LHB) tendon instead of previously explored fascia lata autograft, thereby reducing harvest site and suture anchor associated complications.

Hypothesis

This novel method of SCR using the LHB is feasible biomechanically in restoring shoulder stability in irreparable supraspinatus tendon tear.

Materials and methods

Seven cadaveric shoulders were tested in a custom shoulder testing system. Superior translation of the humerus, subacromial contact pressure and area, and glenohumeral range of motion were tested at 0°, 30°, and 60° of glenohumeral abduction in the following conditions: (1) intact shoulder, (2) simulated complete supraspinatus tendon tear, (3) modified SCR using LHB, (4) and modified SCR using LHB and side-to-side repair augmentation.

Results

The complete cuff tear shifted the humeral head superiorly as compared to the intact shoulder. Subacromial peak contact pressure was also increased at 30° and 60° while contact area was increased at 0° and 30°. The modified SCR both with and without side-to-side repair shifted the humeral head inferiorly at 30° and 60°, with contact area further reduced at 60°. Both techniques had comparable results for contact pressure and total rotational range of motion.

Conclusion

The LHB with appropriate distal insertion on the greater tuberosity restores shoulder stability in irreparable rotator cuff tears by re-centering the humeral head on the glenoid.

Level of evidence

Basic science study, biomechanical testing.

El texto completo de este artículo está disponible en PDF.

Keywords : Superior capsular reconstruction, Irreparable rotator cuff tear, Long head of biceps, Biomechanical study, Cadaveric study


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 2

P. 257-263 - avril 2019 Regresar al número
Artículo precedente Artículo precedente
  • The “Auto-Constant”: Can we estimate the Constant-Murley score with a self-administered questionnaire? A pilot study
  • Mikaël Chelli, Yohann Levy, Vincent Lavoué, Gilles Clowez, Jean-François Gonzalez, Pascal Boileau
| Artículo siguiente Artículo siguiente
  • An arthroscopic technique for full-thickness rotator cuff repair by transposition of the long head of biceps
  • Jian Lin, Weihui Qi, Zhongtang Liu, Kai Chen, Xiaobin Li, Yingzhao Yan, Xinxian Xu, Xinghe Xue, Yang Yang, Xiaoyun Pan

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.