Suscribirse

Can objective criteria for poor tolerance of proximal humerus malunion be identified? - 31/03/19

Doi : 10.1016/j.otsr.2018.11.020 
Aude Griffart a, , Pauline Joly-Monrigal b, Julien Andrin b, Cyril Lazerges b, Michel Chammas b, Bertrand Coulet b
a Service de chirurgie orthopédique, hôpital de La Cavale Blanche, CHU, boulevard Tanguy-Prigent, 29200 Brest cedex, France 
b Service de chirurgie de la main et du membre supérieur, chirurgie des nerfs périphériques, hôpital Lapeyronie, CHU, 371, avenue du doyen Gaston-Giraud, 34000 Montpellier cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Malunion of the proximal humerus is common and variably tolerated. Classifications developed for proximal humerus malunion (PHM) rely on standard radiographs, which underestimate bone fragment displacement and lack accuracy. The clinical tolerance of PHM is subjective, and revision surgery is not always necessary. The primary objective of this study was to assess the reproducibility and relevance of four CT angle measurements for objectively quantifying the morphological disharmony caused by PHM in a control population then in a population with PHM. The secondary objectives were to identify angle cut-offs and to assess the correlations between angle values and the clinical tolerance of PHM.

Hypothesis

Objective criteria for assessing proximal humerus malunion can be identified using CT scans.

Materials and methods

Four angles were chosen to quantify proximal humerus disharmony: the angles between the humeral head and the glenoid in the coronal plane (HGCo) and axial plane (HGAx), the angle of tuberosity divergence in the axial plane (TDAx), and the centrum collum diaphyseal angle (CCD). The reproducibility of measurements of the four angles on computed tomography (CT) views was evaluated in a control population and in 46 patients with PHM. To this end, the reproducibility of reference slice selection was determined and intra- and interobserver reproducibility of the angle measurements was then assessed. Patients with PHM were divided into two groups based on clinical tolerance to allow testing for disharmony parameters associated with poor clinical tolerance, which was defined as functional impairment and surgical revision.

Results

Slice selection was found to be reproducible. The Bland-Altman plot indicated that the angle measurements in both the controls and the patients were reproducible within ±2 SDs. Intraclass correlation coefficient values ranged from fair to excellent for all angles in both the controls and the patients. The mean TDAx was higher in the patients than in the controls (72.0° vs. 56.1°, P<0.05) and, within the PHM group, was higher in the subgroup with good vs. poor clinical tolerance (75.8° vs. 69.5°, P<0.05). The CCD angle was greater in the controls than in the patients (129.8° [range, 128.3°–131.3°] vs. 125.9° [range, 122.9°–128.9], respectively) and was significantly greater in the PHM subgroup with good vs poor clinical tolerance (131.4° vs. 122.3°, respectively; P=0.007). The HGCo and HGAx angles were significantly greater in the patients than in the controls (HGCo: 66.6° vs. 52.2°, respectively; HGAx: 17.5° vs. 13.3°, respectively, P=0.55).

Discussion

The measurement method described here provides a quantitative assessment of postfracture disharmony based on four angles, the HGCo, HGAx, and TDAx. Measurement of these four angles on CT images was found to have good intra- and interobserver reproducibility. The angle values were significantly greater in the patients with PHM than in the controls. Within the patient group, the subgroup with poor clinical tolerance had smaller values of the TDAx, CCD, and HGAx angles and a greater value of the HGCo angle.

Level of evidence

IV, retrospective observational study.

El texto completo de este artículo está disponible en PDF.

Keywords : Malunion, Shoulder, Fractures, Interobserver reliability: Intraobserver reproducibility: Computed tomography


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 2

P. 291-299 - avril 2019 Regresar al número
Artículo precedente Artículo precedente
  • Gleno-humeral abduction measurement in patients with Ehlers-Danlos syndrome
  • David Cypel
| Artículo siguiente Artículo siguiente
  • Is the Charlson comorbidity index a good predictor of mortality and adverse effects in proximal humerus fractures?
  • Ana Belén Fernández-Cortiñas, Jesús Vidal Campos, Xavier Paredes-Carnero, Fernando Marco Martinez

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.