Suscribirse

Mechanical thrombectomy with a novel stent retriever with multifunctional zones: Initial clinical experience with the NeVa™ thrombectomy device - 14/04/19

Doi : 10.1016/j.neurad.2019.03.007 
M. Ribo a, , M. Requena a, J. Macho b, J. Zamarro c, P. Machi d, D. Hernandez e, J. Blasco b, A. Tomasello e
a Stroke Unit, Department of Neurology, Vall d’Hebron University Hospital, Barcelona, Spain 
b Angioradiology Section, Clinic Hospital, Barcelona, Spain 
c Department of Neuroradiology, Virgen de la Arrixaca University Hospital, Murcia, Spain 
d Centre Hospitalier Universitaire Gui de Chauliac, Montpellier, France 
e Department of Neuroradiology, Vall d’Hebron University Hospital, Barcelona, Spain 

Corresponding author at: Passeig Vall d’Hebron 119-121, 08035 Barcelona, Spain.Passeig Vall d’Hebron 119-121Barcelona08035Spain
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Sunday 14 April 2019
This article has been published in an issue click here to access

Abstract

Background and purpose

The NeVa™ (Vesalio, Nashville, Tennessee) thrombectomy device is a CE-approved novel hybrid-cell stent retriever with offset enlarged openings coupled with functional zones and a closed distal end. The device was designed to incorporate and trap resistant emboli. The purpose was to determine the safety and efficacy of the NeVa™ stent.

Methods

Prospective data was collected on the first thirty consecutive patients treated at four stroke centers with NeVa™ as first line treatment between December 2017 and May 2018. Clinical outcome measures included re-perfusion scores after each pass, complications (per-procedural complications, device related adverse events, all intracerebral hemorrhage (ICH) and symptomatic ICH (sICH) on follow up imaging), 24 hour NIHSS, mRS at discharge and 90 days. Baseline data as well as treatment parameters were documented.

Results

Mean presenting NIHSS was 16. Sites of primary occlusion were 10 ICA, 16 M1-MCA, 3 M2-MCA and one basilar. There were five tandem occlusions. Reperfusion outcomes after each NeVa pass; TICI ≥ 2b after first pass 63%, after 1 or 2 passes 83%, after 1 to 3 passes 90%. TICI 2c-3 after first pass 47%, after 1-2 passes 57%, after 1–3 passes 60%. TICI ≥ 2b after final pass 93%; TICI 2c-3, 63%. There were no device related serious averse events and no sICH. Clot material was partially or completely incorporated into the device after 70% passes. The mean 24 hour NIHSS was 7 and the 90 day mRS was 0–2 in 53%.

Conclusions

The NeVa™ device demonstrated a high rate of first pass complete reperfusion effect, a good safety profile and favorable 90 day clinical outcomes in this initial clinical experience.

El texto completo de este artículo está disponible en PDF.

Keywords : Thrombectomy, Device, Stroke


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.