Suscribirse

The diagnostic accuracy of 1.5 T versus 3 T non-echo-planar diffusion-weighted imaging in the detection of residual or recurrent cholesteatoma in the middle ear and mastoid - 05/05/19

Doi : 10.1016/j.neurad.2019.02.013 
L.M.J Lips a, , P.J. Nelemans b, F.M.D. Theunissen a, E. Roele a, J. van Tongeren c, J.R. Hof c, A.A. Postma a
a Department of radiology, Maastricht University Medical Centre, Postbus 5800, 6202 AZ Maastricht, The Netherlands 
b Department of Epidemiology, Maastricht University Medical Centre, Postbus 5800, 6202 AZ Maastricht, The Netherlands 
c Department of Otorhinolaryngology. Maastricht University Medical Centre, Postbus 5800, 6202 AZ Maastricht, The Netherlands 

Corresponding author.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Sunday 05 May 2019
This article has been published in an issue click here to access

Abstract

Purpose and background

This study retrospectively compares diagnostic performance of 1.5 T versus 3 T non-echo planar diffusion weighted imaging with or without additional T1 and T2 sequences in the detection of residual and/or recurrent cholesteatoma.

Methods

Patients with clinically suspected recurrent cholesteatoma or postoperative routine survey MR who subsequently underwent surgical procedure were retrospectively included (135 patients, 164 operated ears) from a large database. Patients underwent 1.5 T (128 ears) or 3 T MRI (36 ears), with non-echo planar DWI, T1 and T2 acquisitions. Two radiologists independently reassessed the images. Definitive surgical diagnosis was used as gold standard. Sensitivity, specificity and diagnostic odds ratio were evaluated.

Results

According to surgical diagnosis a cholesteatoma was present in 124 of 164 ears, corresponding with a prevalence of 75%. Sensitivity and specificity were lower for 3 T compared to 1.5 T, irrespective of whether additional T1 and T2-weighted sequences were used or not. Diagnostic odds ratios were higher for 1.5 T (34 and 12 for reader 1 and 2, respectively) compared to 3 T (3 and 4 for reader 1 and 2, respectively). Adding T1 and T2 sequences lowers sensitivity but increases specificity.

Conclusion

Non-epi DWI for the detection of residual/recurrent cholesteatoma is preferably performed on 1.5 T scanners over 3 T. The use of additional sequences regarding detection of cholesteatoma is debatable as it lowers sensitivity but increases specificity. However, these sequences may also be of use in diagnosing complications and planning surgical procedures in some hospitals.

El texto completo de este artículo está disponible en PDF.

Keywords : Mesh, Cholesteatoma, Ear, middle, Temporal bone, Magnetic resonance imaging (diffusion weighted imaging), Non-epi diffusion weighted imaging, Data accuracy


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.