Suscribirse

Same-eye comparison of pupillary dilation with an intraoperative standardized intracameral combination of mydriatics (Mydrane®) versus a preoperative ophthalmic (Mydriasert®) in standard cataract surgery in non-diabetic patients - 20/08/19

Doi : 10.1016/j.jfo.2019.07.001 
A. de Faria a, , R. Giorgi b, M. Cohen Salmon c, S. Bonnel a, G. Holweck a, A. Le Corre a, E. Chazalon a
a Ophthalmology, HIA Laveran, 13000 Marseille, France 
b Department of Public Health (BIOSTIC), hôpital la Timone, APHM, 13000 Marseille, France 
c Ophthalmology, APHM, 13000 Marseille, France 

Corresponding author.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Tuesday 20 August 2019
This article has been published in an issue click here to access

Summary

Introduction

Cataract surgery is the most commonly performed surgery in the world, and its success depends in part on the quality of mydriasis.

Purpose

To compare, for the same eye, the pupillary dilation obtained with Mydrane® (standardized intracameral solution of 0.02% tropicamide, combined with 0.31% phenylephrine and 1% lidocaine) intraoperatively versus Mydriasert® (0.28mg tropicamide insert and 5.4mg phenylephrine) with a contact time between 45 and 60 minutes in the preoperative period.

Methods

Single center prospective study from November 2016 to January 2018 at the Laveran Army Instructional Hospital in Marseille. Patients referred for surgery were dilated at the preoperative consultation with Mydriasert®. The pupillary diameter after 45–60 minutes of contact with the insert was manually measured, by two different examiners, through the “iris image” tab of the Pentacam® elevation topography. Patients were dilated on the day of their cataract surgery with 0.2cc of Mydrane® injected in the anterior chamber through a paracentesis. Thirty seconds later, prior to injection of viscoelastic, an eye photograph was taken by screen capture. The pupillary diameter was evaluated by two different examiners with to the Piximeter 5.9 metrology software. The difference in pupil dilation between Mydriasert® and Mydrane® was tested with the paired series Student t-test.

Results

A hundred and eleven eyes of 82 patients were included. Mydriasert® achieved a mean pupillary dilation of 7.21±0.79mm. The mydriasis obtained with Mydrane® averaged 6.35±0.8mm. This difference of 0.86mm was statistically significant (P<0.001) with a confidence interval of 95% [−0.97; −0.74].

Conclusion

On average, Mydrane® dilates the pupil less than Mydriasert®. However, the mydriasis obtained with Mydrane® remains comfortable for the performance of the capsulorhexis. It helps save preoperative time and affords additional anesthetic to the cataract surgery. Nevertheless, the use of Mydriasert® is beneficial when extra mydriasis is required.

El texto completo de este artículo está disponible en PDF.

Keywords : Cataract surgery, Pupillary dilation, Mydriasis, Mydriatics, Mydriatic insert, Mydriasert®, Intracameral injection, Mydrane®


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.