Suscribirse

Percutaneous transluminal angioplasty alone versus stent placement for the treatment of transplant renal artery stenosis - 24/08/19

Doi : 10.1016/j.diii.2019.03.010 
M. Macchini a, b, , T. Mokrane a, J. Darcourt a, J. Bellière c, N. Kamar c, R. Candelari b, H. Rousseau a, O. Meyrignac a
a Department of Radiology, CHU de Toulouse Rangueil, 31400 Toulouse, France 
b Interventional Radiology, Department of Radiology, Az. Osp-Univ OORR-Torrette, Via Conca 71, 60126 Ancona, Italy 
c Department of Nephrology, CHU Toulouse Rangueil, 31400 Toulouse, France 

Corresponding author at: Interventional Radiology, Department of Radiology, Az. Osp-Univ OORR-Torrette, Via Conca 71, 60126 Ancona, Italy.Interventional Radiology, Department of Radiology, Az. Osp-Univ OORR-TorretteVia Conca 71Ancona60126Italy

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purposes of this retrospective study were to assess the efficacy of endovascular techniques for the treatment of transplant renal artery stenosis (TRAS) by analyzing technical and clinical success and to compare the results of percutaneous transluminal angioplasty (PTA) alone to those of stenting.

Materials and methods

A retrospective analysis was conducted on 31 patients who underwent endovascular treatment for TRAS between January 2012 and December 2017. There were 23 men and 8 women with a mean age of 60.5±14 (SD) years (range: 24–81 years). Ten patients (10/31; 32%; 8 men, 2 women; median age, 63 years) were treated with PTA alone and 21/31 (68%; 15 men, 6 women; median age, 65 years) with metallic stent placement. Several variables including serum creatinine level, glomerular filtration rate, arterial blood pressure value, antihypertensive medication obtained before and after treatment were compared. Technical success was assessed for each procedure. Clinical success was defined as a 15% drop in serum creatinine level, a decrease greater than 15% in mean blood pressure values or a decrease greater than 10% in mean blood pressure values with a reduction in the number of antihypertensive drugs needed for hypertension control.

Results

Technical success was obtained in all patients [31/31; 100%; 95% confidence interval (CI): 89–100%] and clinical success in 27/31 patients (87%; 95%CI: 71–95%). Four patients (4/31; 13%; 95%CI: 5–29%) underwent repeat endovascular intervention. Mean serum creatinine level and mean arterial blood pressure values were significantly lower after treatment (177.4 and 93.8μmol/l, respectively) compared to before treatment (319.4 and 106.7μmol/l, respectively) in the stent group but not in the group treated with PTA alone (P=0.0012 and P=0.002, respectively).

Conclusion

The endovascular approach is safe and effective in the management of TRAS and stenting, depending on the morphology of the stenosis, should be the treatment of choice when possible.

El texto completo de este artículo está disponible en PDF.

Keywords : Renal artery obstruction, Kidney transplantation, Endovascular procedures, Angioplasty, Stent


Esquema


© 2019  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 9

P. 493-502 - septembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Central venous occlusion in hemodialysis access: Comparison between percutaneous transluminal angioplasty alone and nitinol or stainless-steel stent placement
  • S. Gür, L. O?uzkurt, M. Gediko?lu
| Artículo siguiente Artículo siguiente
  • Virtual unenhanced phase with spectral dual-energy CT: Is it an alternative to conventional true unenhanced phase for abdominal tissues?
  • S. Jamali, N. Michoux, E. Coche, C.A. Dragean

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.