Suscribirse

Virtual unenhanced phase with spectral dual-energy CT: Is it an alternative to conventional true unenhanced phase for abdominal tissues? - 24/08/19

Doi : 10.1016/j.diii.2019.04.007 
S. Jamali , N. Michoux, E. Coche, C.A. Dragean
 Department of Radiology, Cliniques universitaires Saint Luc, Avenue Hippocrate 10, 1200 Woluwé Saint Lambert, Brussels, Belgium 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To compare attenuation measurements and image quality of virtual unenhanced phase (VUP) images with those of conventional true unenhanced phase (TUP) images on spectral dual energy computed tomography (DECT) with dual layer detector on abdominal tissues and to assess potential reduction in radiation dose.

Material and method

A total of 295 patients (185 men, 110 women; mean age 61±17.6 [SD] years [range: 17–95 years]) who had undergone abdominal or thoraco-abdominal CT with pre- and post-contrast imaging (portal phase) with spectral DECT with dual layer detector were retrospectively analyzed. VUP images based on portal-venous phase DECT acquisition were generated. Regions of interest were defined in abdominal tissues (liver, spleen, kidney, muscle and fat) by two independent readers. Inter-technique agreement (VUP images vs. TUP images) on attenuation measurements was assessed. Signal-to noise ratio (SNR) and image quality of TUP and VUP images were compared. The radiation dose delivered to patients was compared with the radiation dose of protocols without TUP images.

Results

A total of 9880 ROIs were drawn in the abdominal tissues. The difference in mean attenuation values between TUP and VUP images was less than 15 HU in 98.3% and less than 10 HU in 92.3% of all measurements. VUP images overestimated attenuation in fat comparatively to TUP images. Image quality was evaluated as good or excellent in 77% (37/48) of TUP images and 54% (26/48) of VUP images. Using VUP images instead of TUP images could decrease the radiation dose by 32%.

Conclusion

VUP images demonstrate good agreement with TUP images in different abdominals tissues and can be obtained with similar image quality as TUP. VUP images appear as an alternative to TUP images, resulting in reduction of radiation dose delivered to the patient.

El texto completo de este artículo está disponible en PDF.

Keywords : Radiography, Dual-energy computed tomography (CT), Projection/methods, Radiation dose


Esquema


© 2019  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 9

P. 503-511 - septembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Percutaneous transluminal angioplasty alone versus stent placement for the treatment of transplant renal artery stenosis
  • M. Macchini, T. Mokrane, J. Darcourt, J. Bellière, N. Kamar, R. Candelari, H. Rousseau, O. Meyrignac
| Artículo siguiente Artículo siguiente
  • Improved contrast for myeloma focal lesions with T2-weighted Dixon images compared to T1-weighted images
  • A. Danner, E. Brumpt, M. Alilet, G. Tio, P. Omoumi, S. Aubry

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.