Suscribirse

Évaluation de l’incidence des lésions de radiodermite en cardiologie interventionnelle - 19/09/19

Evaluation of the incidence of radiodermatitis lesions in interventional cardiology

Doi : 10.1016/j.ancard.2019.08.002 
T.I. Matei , A. Paziuc, P. Mester, A. Ispas, P. Puie, L. Blaga, J. de Quatrebarbe, F. Maniora, S. Vanwalleghem, H. Madiot, C. Ricard, L. Mangin, L. Belle
 Centre hospitalier Annecy-Genevois, 1, avenue de l’Hôpital, 74370 Metz-Tessy, France 

Auteurs correspondants.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Thursday 19 September 2019
This article has been published in an issue click here to access

Résumé

But de l’étude

Les interventions coronaires percutanées utilisent des doses importantes de rayonnements ionisants, en particulier lors du traitement de lésions complexes. L’incidence des lésions cutanées radio induites est peu connue. Notre objectif a été d’évaluer la fréquence d’apparition de telles lésions, ainsi que les facteurs pouvant contribuer à une dose de rayonnement élevée. Le seuil de DAP (produit dose-surface, eng. dose-area product) recommandé pour une surveillance cutanée après interventions coronariennes percutanées est de 500Gy cm2.

Patients et méthode

Nous avons étudié d’une façon prospective la fréquence d’apparition de lésions cutanées aiguës (après 5 à 7jours) et subaiguës (après 7jours à 6 mois) après une angioplastie avec un DAP ≥200Gy cm2 chez les patients ayant bénéficié d’une angioplastie coronaire dans notre centre en 2013.

Résultats

Neuf cent trente sept procédures consécutives ont été analysées, dont 102 avec un DAP ≥200Gy cm2. Trois patients ont présenté une lésion aiguë. Deux de ces trois patients ont présenté également des lésions subaigües. Un autre patient a présenté seulement une lésion subaiguë. Au total, 4,82 % (IC95 % : [0–10]) des patients avec un DAP ≥200Gy cm2 ont développé des lésions de radiodermite, soit 0,47 % (IC95 % : [0–0,9]) de tous les patients ayant bénéficié d’une angioplastie. L’Indice de masse corporelle et les procédures électives (par opposition aux urgentes) ont été indépendamment associés à une procédure avec DAP ≥200Gy cm2.

Conclusion

Les lésions de radiodermite surviennent pour 4,82 % des patients bénéficiant des procédures avec un DAP ≥200Gy cm2. Nous suggérons l’établissement d’un seuil du DAP pour la surveillance cutanée des patients de 200Gy cm2 par procédure au lieu de 500Gy cm2.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The percutaneous coronary interventions use large doses of ionizing radiation, particularly when treating complex lesions. The incidence of radio-induced skin lesions is poorly known. Our goal was to evaluate the frequency of occurrence of such lesions, as well as the factors that may contribute to a high radiation dose. The recommended DAP (dose-area product) cutoff for skin monitoring after percutaneous coronary interventions is 500Gy cm2.

Patients and method

We prospectively studied the incidence of acute (after 5–7 days) and subacute (after 7 days to 6 months) skin lesions following angioplasty with a dose-area product (DAP) ≥200Gy cm2 in patients who underwent coronary angioplasty in our center in 2013.

Results

Nine hundred and thirty three consecutive procedures were analyzed, of which 102 with a DAP ≥200Gy cm2. Three patients presented an acute lesion. Two of these three patients also had subacute lesions. Another patient presented only a subacute lesion. 4.82% (95% CI: [0–10]) of the patients with a DAP ≥200Gy cm2 developed radiodermitis lesions, or 0.47% (95% CI: [0–0.9]) of all the patients who underwent angioplasty.

The Body Mass Index and the elective (as opposed to energy) procedures were independently associated with a procedure with a DAP ≥200Gy cm2.

Conclusion

Radiodermatitis lesions occur for 4.82% of patients benefiting from procedures with a DAP ≥200Gy cm2. We suggest the establishment of a DAP threshold for dermal monitoring of patients of 200Gy cm2 per procedure instead of 500Gy cm2.

El texto completo de este artículo está disponible en PDF.

Mots clés : Rayonnement, Angioplastie, Produit dose- surface, Lésion cutanée, Radiodermite, PCI, DAP

Keywords : Radiation, Angioplasty, Dose-area product, Skin lesion, Radiodermatitis, PCI, DAP


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.