Suscribirse

Biomechanical comparison of different tendon suturing techniques for three-stranded all-inside anterior cruciate ligament grafts - 19/09/19

Doi : 10.1016/j.otsr.2019.06.007 
Jae-Sung Yoo a, Sung Jae Lee b, Ji Eun Jang b, Youngwoong Jang c, Chaneol Kim c, Yong In d,
a Department of Orthopedic Surgery, Dankook University College of Medicine, Cheonan, Republic of Korea 
b Department of Biomedical Engineering, Inje University, Gimhae, Republic of Korea 
c Central R&D Center, Corentec Co. Ltd, Seoul, Republic of Korea 
d Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-Daero, Seocho-Gu, Seoul 06591, Republic of Korea 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Objective

In all-inside anterior cruciate ligament (ACL) reconstruction, it is usually difficult to obtain sufficient autologous semitendinosus tendon length for quadruple stranded graft in Asians, females, and those with short stature. The purpose of this study was to compare biomechanical properties of three different types of suture preparations for tripled graft and determine which method could achieve sufficient strength for ACL through in vitro study. The hypothesis of this study was that suturing with a rip-stop (RS) stitch for tripled-strand graft would lead to stronger mechanical properties than suturing with buried-knot four sutures.

Methods

Twenty-four bovine digital extensor tendons harvested from forelimbs were prepared for tripled-strand graft in three different ways: (1) buried-knot four sutures, (2) two RS sutures, and (3) four RS sutures. These grafts were directly connected to cylindrical metal rods of a tensile testing machine. All specimens underwent cyclic loading followed by a load-to-failure test. Preparation time, elongation, stiffness, and ultimate failure load were compared.

Results

For biomechanical comparison, the group with buried-knot four sutures was excluded because six (75%) specimens failed during the cycle load test. The group with four RS sutures showed lower total elongation (two RS sutures: 8.42±5.28mm; four RS sutures: 3.86±0.83mm, p=0.030), higher stiffness (two RS sutures: 247.28±53.39N/mm; four RS sutures: 329.27±55.56N/mm, p<0.001), and higher ultimate failure load (two RS sutures: 567.74±60.50N; four RS sutures: 736.46±32.50N, p=0.009). The most common failure mechanism of triple stranded graft was tendon split across sutures.

Conclusion

The method with four RS sutures showed sufficient strength for triple stranded graft for all-inside ACL reconstruction without increasing preparation time.

Level of evidence

III, controlled laboratory study.

El texto completo de este artículo está disponible en PDF.

Keywords : Anterior cruciate ligament, Reconstruction, All-inside technique, Triple stranded graft, Biomechanics


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 6

P. 1101-1106 - octobre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Is intraoperative fluoroscopy necessary in anterior cruciate ligament double-bundle reconstruction? A prospective randomized controlled trial
  • Ji Hyun Ahn, Sangwoo Kim, Jaehyun Kim
| Artículo siguiente Artículo siguiente
  • The effect of knee bracing on the knee function and stability following anterior cruciate ligament reconstruction: A systematic review and meta-analysis of randomized controlled trials
  • Xiong-gang Yang, Jiang-tao Feng, Xin He, Feng Wang, Yong-cheng Hu

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.