Suscribirse

Dose reduction in perfusion CT in stroke patients by lowering scan frequency does not affect automatically calculated infarct core volumes - 11/10/19

Doi : 10.1016/j.neurad.2019.04.004 
Grzegorz Marek Karwacki , Stephan Vögele, Kristine Ann Blackham
 University Hospital Basel, University of Basel, clinic of radiology and nuclear medicine, Basel, Switzerland 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 8
Iconografías 8
Vídeos 0
Otros 0

Graphical abstract




El texto completo de este artículo está disponible en PDF.

Highlights

Despite lowering CTP scan frequency automatically calculated infarct core volume based on CBV is equivalent to the one based on standard CTP.
Reduction of radiation exposure in CTP without objective loss of accuracy of automatically calculated infarct core volume is feasible.
Lowering CTP scan frequency might lead to significant infarct core overestimation in individual cases when using CBV.
Using rMTT for automatic volume calculation of penumbra in low frequency CTP is not advisable as it does not deliver results equivalent to the ones based on standard CTP.

El texto completo de este artículo está disponible en PDF.

Abstract

Background and purpose

CT Perfusion technique (CTP) is a quantitative, easily performed, accepted and reliable method for detection of ischemic brain changes. Based on calculated parameters, the size of ischemic penumbra and irreversibly damaged infarct core can be determined which helps guide treatment decisions. However, due to the dynamic nature of the CTP study, it is dose intensive. This study determines the consequences of retrospectively reducing the number of scans in the dynamic acquisition by half on the volume of the automatically calculated infarct core (non-viable tissue) and penumbra (tissue at risk) volumes. Our hypothesis was that equivalent volumetric information could be obtained at a substantial dose savings.

Materials and methods

Fifty one consecutive patients with occlusion of M1 and/or M2 segment of the middle cerebral artery and ischemic stroke proven by follow-up MRI were included. CTP scans were first analyzed in a standard fashion and automatically generated volumes measured in milliliters were recorded in a database. A second analysis was conducted after removing every second data acquisition from the sequential CTP scans. Automatic volume measurements were repeated, recorded and compared to the initial values obtained using the full dataset.

Results

The two CTP protocols were statistically equivalent pertaining to automatic infarct core volume calculation but a case-by-case analysis revealed substantial overestimation in some cases.

Conclusion

Reduction of radiation exposure in CTP without objective loss of accuracy of automatically calculated infarct core volume is feasible but might lead to clinically relevant infarct core overestimation in individual cases.

El texto completo de este artículo está disponible en PDF.

Keywords : Stroke, CT Perfusion, Penumbra, Infarct, Volume


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 46 - N° 6

P. 351-358 - novembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography: Patient and phantom study
  • Yunsun Song, Youngeun Kim, Seongsik Han, Tae Il Kim, Joon Ho Choi, Jun Young Maeng, Youngrak Choi, Deok Hee Lee
| Artículo siguiente Artículo siguiente
  • Comparison between MRI-derived ADC maps and 18FLT-PET in pre-operative glioblastoma
  • David Hassanein Berro, Solène Collet, Jean-Marc Constans, Louisa Barré, Jean-Michel Derlon, Evelyne Emery, Jean-Sébastien Guillamo, Samuel Valable

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.