Agreement of intracranial vessel diameters measured on 2D and 3D digital subtraction angiography using an automatic windowing algorithm - 12/10/19

Doi : 10.1016/j.neurad.2019.08.004 
Y. Abe a, , I. Yuki b, K. Otani c, T. Shoji a, T. Ishibashi b, Y. Murayama b
a Department of Radiology, The Jikei University Hospital, Tokyo, Japan 
b Department of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan 
c Siemens Healthcare K.K., Tokyo, Japan 

Corresponding author. Department of Radiology, The Jikei University Hospital, 3-19-18, Nishi-Shinbashi, 105-8461 Minato-ku, Tokyo, Japan.Department of Radiology, The Jikei University Hospital3-19-18, Nishi-ShinbashiMinato-ku, Tokyo105-8461Japan
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Saturday 12 October 2019
This article has been published in an issue click here to access

Graphical abstract




El texto completo de este artículo está disponible en PDF.

Highlights

Auto window optimizes the windowing of 3D DSA images in a reproducible way.
Vessel diameters on 2D and 3D DSA images showed excellent correlation.
Vessel diameters on 2D and 3D DSA images were in good or excellent agreement.

El texto completo de este artículo está disponible en PDF.

Abstract

Background and purpose

Precise vessel measurement plays a major role in size selection of stents used for the treatment of intracranial aneurysms and became even more critical after the introduction of flow diverter stents. We assessed agreement between intracranial vessel diameters of aneurysm patients measured on 2D digital subtraction (2D DSA) and 3D volume rendering digital subtraction angiography (3D DSA) images using an automatic windowing algorithm.

Materials and methods

Ten patients with intracranial aneurysms were enrolled and 120 measurement points were selected on both 2D and 3D DSA images acquired by a biplane angiographic system. Automatic windowing was applied to the 3D DSA images. Inter-method agreement of vessel measurements on 2D and 3D DSA images was assessed by Bland Altman plots and intraclass correlation coefficients (ICC). Inter- and intra-rater agreement of measurements on 3D DSA images were assessed by ICCs.

Results

The mean differences between measurements on 2D and 3D DSA images were 0.14mm for the ICA, and 0.18mm for the ACA and MCA, which is about the size of one 3D DSA image voxel. For ICA measurements, inter-method, inter-rater and intra-rater agreements were good or excellent (consistency and absolute ICC0.95). For ACA and MCA measurements, the inter-method, inter-rater and intra-rater agreements were also good or excellent (consistency ICC=0.94, 0.89 and 0.93, absolute ICC=0.83, 0.84 and 0.85 respectively).

Conclusions

Vessel diameters may be measured on 3D DSA images with sufficient reliability for clinical use when applying an automatic windowing algorithm.

El texto completo de este artículo está disponible en PDF.

Keywords : Intracranial aneurysm, 3D-DSA, Angiography, Vessel measurement


Esquema


© 2019  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.