Suscribirse

Long-term survival of hybrid total hip arthroplasty with the uncemented CLS cup, cemented Müller cobalt-chromium stem, and 28-mm Metasul™ bearings: Retrospective review of 115 hips after a minimum of 17.8 years - 07/11/19

Doi : 10.1016/j.otsr.2019.06.019 
Roger Erivan a, , Guillaume Villatte a, Thibaut Lecointe b, Aurélien Mulliez c, Stéphane Descamps a, Stéphane Boisgard a
a Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont–Ferrand, France 
b Université Clermont Auvergne, CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France 
c Délégation à la Recherche Clinique et aux Innovations (DRCI), CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France 

Corresponding author at: Orthopaedic and Trauma Surgery Department, Hôpital Gabriel-Montpied, CHU de Clermont-Ferrand, BP 69, 63003 Clermont-Ferrand, France.Orthopaedic and Trauma Surgery Department, Hôpital Gabriel-Montpied, CHU de Clermont-FerrandBP 69Clermont-Ferrand63003France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Hard-on-hard bearings require a meticulous implantation technique but may be associated with lower wear rates in young active patients. Among them, metal-on-metal (MoM) bearings have been blamed for specific complications including adverse reactions to metal debris and metal hypersensitivity. These complications have been chiefly reported with large-head MoM implants (except when used for hip resurfacing). Most of the published data on small-head MoM implants were obtained using uncemented stems. To our knowledge, no information on outcomes beyond 15 years is available for small-head MoM implants with cemented cobalt-nickel-chromium (Co-Ni-Cr) stems, which might increase the risk of complications. The objective of this study was to collect long-term follow-up data on patients who underwent hybrid total hip arthroplasty (THA) with 28-mm MoM Metasul™ bearings in order to assess: (1) long-term survival (based on the revision rate), (2) and the occurrence of adverse reactions to metal debris documented during revision.

Hypothesis

Survival of 28-mm Metasul™ bearings used with hybrid THA is acceptable.

Patients and methods

A single-centre retrospective study was conducted in consecutive patients managed using 28-mm Metasul™ bearings in a press-fit cup, with a cemented Co-Ni-Cr stem. Follow-up was at least 17 years. The clinical and radiographic data were analysed. Mean age at surgery was 57.3±7.9 years (range, 29.6–75.3 years).

Results

The study included 115 hips with a mean follow-up of 20.3±0.8 years (range, 17.8–21.6 years). Survival to revision for any reason was 86.10% (95% CI, 79.8–92.4%) and survival to revision for aseptic loosening was 92.6% (95% CI, 87.7–97.6). Half the specimens obtained during revision showed a macrophage reaction and a non-specific inflammatory infiltrate. No patient experienced complications specifically related to the use of Metasul™ bearings with a cemented Co-Ni-Cr stem.

Discussion

Long-term survival of 28-mm MoM Metasu™ bearings was close to that of metal-on-polyethylene bearings and lower than that of ceramic-on-ceramic or small-head MoM bearings in other studies. No complications specifically related to the use of small-head MoM bearings with a cemented Co-Ni-Cr stem were recorded.

Level of evidence

IV, retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Aseptic lymphocyte-dominated vasculitis-associated lesion, Adverse reaction to metal debris, Metal-on-metal, Total hip arthroplasty, Survival


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 7

P. 1289-1295 - novembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Texture analysis of trabecular bone around RM-Pressfit cementless acetabulum in a series of 46 patients during a 5 year period
  • Augustin Coupry, Louis Rony, Florian Ducellier, Laurent Hubert, Daniel Chappard
| Artículo siguiente Artículo siguiente
  • Patients with musculoskeletal dysplasia undergoing total joint arthroplasty are at increased risk of surgical site Infection
  • Harshadkumar Patel, Kyle H. Cichos, Andrew S. Moon, Gerald McGwin, Brent A. Ponce, Elie S. Ghanem

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.