Suscribirse

Texture parameters of R2* maps are correlated with iron concentration and red blood cells count in clot analogs: a 7T micro-MRI study - 11/11/19

Doi : 10.1016/j.neurad.2019.10.004 
Martin Bretzner 1, 2,  : Dr, Renaud Lopes 1, 2, Ray McCarthy 3, Delphine Corseaux 4, 5, 6, Florent Auger 1, Gillian Gunning 3, Nicolas Beauval 7, 8, 9, Antonino Bongiovanni 10, Meryem Tardivel 10, Charlotte Cordonnier 11, Jean-Pierre Pruvo 1, 2, Sophie Susen 4, 5, 6, Xavier Leclerc 1, 2, Grégory Kuchcinski 1, 2
1 University of Lille, INSERM U1171 Troubles cognitifs dégénératifs et vasculaires, 59000, Lille, France 
2 CHU Lille, Service de Neuroradiologie, 59000, Lille, France 
3 Cerenovus, Galway, Ireland 
4 Inserm U1011-EGID, Lille, France 
5 Institut Pasteur de Lille, Lille, France 
6 CHU Lille, Hématologie Transfusion, Lille, France 
7 Bio Imaging Center Lille Nord-de-France Campus HU, Université de Lille, Faculté de Médecine, 59000, Lille, France 
8 IMT Lille Douai, Sciences de l’Atmosphère et Génie de l’Environnement (SAGE), 59508, Douai cedex, France 
9 Université de Lille, 59000, Lille, France 
10 Université Lille, CNRS, CHU Lille, Institut Pasteur de Lille, INSERM U1019–UMR 8204, CIIL–Center for Infection and Immunity of Lille, 59000, Lille, France 
11 CHU Lille, Service de Neurologie, 59000, Lille, France 

Address correspondence to: CHU Lille, Department of Neuroradiology, Rue Emile Laine, F-59000, Lille, FranceCHU Lille, Department of Neuroradiology, Rue Emile LaineLilleF-59000France
En prensa. Manuscrito Aceptado. Disponible en línea desde el Monday 11 November 2019
This article has been published in an issue click here to access

Highlights

RBC count is strongly correlated with iron concentration within clots.
Texture analysis of R2* maps predict the RBC count and iron content of clot analogs.
R2* maps of RBC rich clots present a more coarse texture.
R2* maps of RBC poor clots present a finer texture.

El texto completo de este artículo está disponible en PDF.

Abstract

Background and purpose: Previous studies have suggested that mechanical revascularization in acute ischemic stroke (AIS) patients could be affected by clot histology. In this 7T micro-MRI study, we used R2* relaxometry of clot analogs to evaluate the relationship between texture parameters of R2* maps and clot constituents.

Materials and Methods: Twelve AIS clot analogs were experimentally generated to obtain a wide range of red blood cell concentrations. All clots underwent a MR acquisition using a 7T micro-MR system. A 3D multi-echo gradient-echo sequence was performed and R2* maps were generated. First order and second order statistics of R2* histograms within the clots were calculated. Iron concentration in clots was measured using absorption spectrometry and red blood cell count (RBC) was obtained by histopathological analysis.

Results: RBC count was strongly correlated with iron concentration within clots (r=0.87, p<.001). Higher RBC count and iron concentration were significantly correlated with first order parameters including: (a) global positive shift of the R2* histogram with higher ‘10th percentile’, ‘median’, ‘mean’ and ‘90th percentile’; (b) increase of the global magnitude of voxel values with higher ‘total energy’ and ‘root mean squared’; (c) greater uniformity of the voxel values with higher ‘uniformity’ and lower ‘entropy’. Second order statistical parameters confirmed that higher RBC count and iron concentration correlated with (a) greater concentration of high gray-level values in the image; (b) more “coarse” texture of R2* maps.

Conclusions: Texture analysis of MRI-R2* maps can accurately estimate the red blood cell count and iron content of AIS clot analogs.

El texto completo de este artículo está disponible en PDF.

Abbreviations : AIS, GLRLM, IV-tPA, MT, NETs, RBC, ROI, VWF

Keywords : MRI, stroke, clot, texture analysis, relaxometry



© 2019  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.