Factors associated with internal rotation outcomes after reverse shoulder arthroplasty - 05/12/19

Doi : 10.1016/j.otsr.2019.07.024 
Morgane Rol a, , Luc Favard a, Julien Berhouet a

la Société d’orthopédie de l’Ouest (SOO)b

a Service d’orthopédie traumatologie, Université François-Rabelais-de-Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-les-Tours, France 
b Société de l'orthopédie de l'ouest SOO, 18, rue de Bellinière, 49800 Trélazé, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Reverse shoulder arthroplasty (RSA) was introduced in 1985 by Grammont for patients with gleno-humeral osteoarthritis and severe rotator cuff damage. Internal rotation (IR) is limited in some patients after RSA. The objective of this study was to identify pre- and intra-operative factors associated with good IR outcomes 6 months after RSA.

Hypothesis

The condition of the residual cuff (usually the sub-scapularis and teres minor) and inferior glenosphere overhang are the main factors associated with IR outcomes after RSA.

Material and Method

A total of 36 patients who underwent RSA between 2 November 2015 and 10 January 2017 were enrolled prospectively. The inclusion criterion was massive rotator cuff tear with or without osteoarthritis and gleno-humeral osteoarthritis with asymmetrical glenoid wear. The pre-operative work-up included determination of the Constant score, Subjective Shoulder Value (SSV), and passive and active motion ranges; standard radiographs; and computed tomography. The same clinical and radiological parameters were recorded in all patients during a visit 6 months after surgery.

Results

After surgery, all motion ranges were improved except IR with the elbow by the side (IR1, ability to place the hand on the back). IR1 to or above L3 was significantly associated with a lower body mass index (p=0.04), good passive IR before surgery (p=0.056), a smaller pre-operative glenoid inclination angle, and greater glenosphere overhang (p=0.03). Neither the condition of the sub-scapularis nor sub-scapularis repair were significantly associated with post-operative IR1. IR1 was significantly more limited in patients whose teres minor was normal.

Conclusion

Satisfactory active IR1 correlated with good passive IR1. IR1 was better in thin individuals who had non-concentric gleno-humeral osteoarthritis. Inferior glenosphere overhang of 6mm or more was associated with a greater range of IR.

Level of evidence

IV, prospective observational cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Reverse shoulder arthroplasty, Outcomes, Joint range of motion, Rotator cuff


Esquema


 Article issued from the SOO (the Orthopedics and Traumatology Society of Western France).


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 8

P. 1515-1519 - décembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Epidemiology and mortality in older patients treated by reverse shoulder arthroplasty for displaced proximal humerus fractures
  • Emmanuel Maugendre, Benjamin Gadisseux, Christophe Chantelot, Philippe Clavert, Nassima Ramdane, Jean-David Werthel, Pascal Boileau, SOFCOT
| Artículo siguiente Artículo siguiente
  • Does ORIF of rare scapular spine fractures sustained after reverse shoulder arthroplasty benefit elderly patients? A case-series appraisal
  • Felix Toft, Fabrizio Moro

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.