Suscribirse

Assessment of proximal femur microarchitecture using ultra-high field MRI at 7 Tesla - 14/12/19

Doi : 10.1016/j.diii.2019.06.013 
D. Guenoun a, b, , M. Pithioux b, J.-C. Souplet c, S. Guis d, T. Le Corroller a, b, A. Fouré c, V. Pauly e, f, J.-P. Mattei d, M. Bernard c, M. Guye c, P. Chabrand b, P. Champsaur a, b, D. Bendahan c
a Department of Radiology, Institute for Locomotion, Sainte-Marguerite Hospital, APHM, 13009 Marseille, France 
b CNRS, ISM, Institute Movement Sci, Aix-Marseille Université, 13000 Marseille, France 
c CNRS, CRMBM UMR 7339, Aix-Marseille Université, 13385 Marseille, France 
d CNRS, CRMBM UMR 7339, Department of Rheumatology, Aix-Marseille Université, AP-HM, 13000 Marseille, France 
e Unité de recherche EA3279, santé publique et maladies chroniques: qualité de vie concepts, usages et limites, déterminants, Aix-Marseille Université, 13005 Marseille, France 
f Service de santé publique et d’information médicale, Hôpital de la Conception, APHM, 13000 Marseille, France 

Corresponding author: Department of Radiology, Institute for Locomotion, Sainte-Marguerite Hospital, APHM, 270, boulevard Sainte-Marguerite, 13009 Marseille, France.Department of Radiology, Institute for Locomotion, Sainte-Marguerite Hospital, APHM270, boulevard Sainte-MargueriteMarseille13009France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

The purpose of this study was to investigate bone microarchitecture of cadaveric proximal femurs using ultra-high field (UHF) 7-Tesla magnetic resonance imaging (MRI) and to compare the corresponding metrics with failure load assessed during mechanical compression test and areal bone mineral density (ABMD) measured using dual-energy X-ray absorptiometry.

Materials and methods

ABMD of ten proximal femurs from five cadavers (5 women; mean age=86.2±3.8 (SD) years; range: 82.5–90 years) were investigated using dual-energy X-ray absorptiometry and the bone volume fraction, trabecular thickness, trabecular spacing, fractal dimension, Euler characteristics, connectivity density and degree of anisotropy of each femur was quantified using UHF MRI. The whole set of specimens underwent mechanical compression tests to failure. The inter-rater reliability of microarchitecture characterization was assessed with the intraclass correlation coefficient (ICC). Associations were searched using correlation tests and multiple regression analysis.

Results

The inter-rater reliability for bone microarchitecture parameters measurement was good with ICC ranging from 0.80 and 0.91. ABMD and the whole set of microarchitecture metrics but connectivity density significantly correlated with failure load. Microarchitecture metrics correlated to each other but did not correlate with ABMD. Multiple regression analysis disclosed that the combination of microarchitecture metrics and ABMD improved the association with failure load.

Conclusion

Femur bone microarchitecture metrics quantified using UHF MRI significantly correlated with biomechanical parameters. The multimodal assessment of ABMD and trabecular bone microarchitecture using UHF MRI provides more information about fracture risk of femoral bone and might be of interest for future investigations of patients with undetected osteoporosis.

El texto completo de este artículo está disponible en PDF.

Keywords : Femur, Osteoporosis, Magnetic resonance imaging (MRI), Mineral bone density, 7 Tesla


Esquema


© 2019  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 1

P. 45-53 - janvier 2020 Regresar al número
Artículo precedente Artículo precedente
  • Annotated normal CT data of the abdomen for deep learning: Challenges and strategies for implementation
  • S. Park, L.C. Chu, E.K. Fishman, A.L. Yuille, B. Vogelstein, K.W. Kinzler, K.M. Horton, R.H. Hruban, E.S. Zinreich, D. Fadaei Fouladi, S. Shayesteh, J. Graves, S. Kawamoto
| Artículo siguiente Artículo siguiente
  • Pelvic hematoma due to spontaneous left iliac vein rupture in May-Thurner syndrome
  • S. Molière, N. Rotaru-Hincu

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.