Suscribirse

Évaluation biomécanique d’une nouvelle technique de stabilisation acromio-claviculaire par réparation directe - 26/01/20

Biomechanical evaluation of a new technique for acromioclavicular stabilization

Doi : 10.1016/j.rcot.2019.12.015 
Ian Peeters a, , Stijn Herregodts a, b, Lieven De Wilde a, Alexander Van Tongel a
a Department of Orthopedic Surgery, Ghent University Hospital, Corneel Heymanslaan, 10, 9000 Gent, Belgique 
b Department of electrical energy, metal, mechanical construction & systems, Ghent University, Technologiepark, 46, 9052 Gent, Belgique 

Auteur correspondant.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Sunday 26 January 2020
This article has been published in an issue click here to access

Abstract

Background

The most commonly used repair techniques to treat an acromioclavicular dislocation imply a suspension mechanism by substituting the supero-inferior oriented coracoclavicular structures with a tight rope mechanism or allograft. Recently, the importance of restoring the antero-posterior stability by addressing the acromioclavicular structures has also been demonstrated. If an in situ repair at the acromioclavicular joint itself could achieve a reposition and would be strong enough, the suspension of the CC structures might become obsolete. Possible advantages would be minimal dissection, lower risk in damaging neurovascular structures, greater stability, reduction of the surgical time and even the possibility of locoregional anesthesia.

Hypothesis

In this biomechanical study, the feasibility of different in situ repair techniques is explored, thereby testing both compression and translation characteristics. Our hypothesis is that an in situ repair technique results in an adequate repair for the AC joint.

Methods and materials

Polyurethane foam blocks will be used as a model for the acromioclavicular joint and the repair techniques will be done by using a combination of sutures and bone anchors or using a transosseous technique. Compression will be measured by means of a Tekscan pressure sensor and translation will be tested in three orthogonal directions using a tensile testing machine. Four different knot anchor configurations (nice knot, surgical knot in two different configurations, nicky's knot) will be tested for compression. The strongest knot anchor configuration will then be compared side to side with a transosseous configuration for translation.

Results

The nice knot in combination with bone anchors provides the strongest compression. In the side to side comparison of a nice knot anchor configuration versus a transosseous nice knot configuration, the transosseous technique shows more resistance to translation.

Discussion

An in situ repair by a combination of the nice knot with an anchor or a transosseous nice knot configuration can theoretically be used as a repair technique for an acromioclavicular dislocation. In comparison with existing techniques, this model shows favorable results for translation.

Level of evidence

III, controlled laboratory study.

El texto completo de este artículo está disponible en PDF.

Keywords : Acromioclavicular joint, Suture technique, Suture anchor, Biomechanics



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.