Suscribirse

Reproducibility assessment of Delaire cephalometric analysis using reconstructions from computed tomography - 28/01/20

Doi : 10.1016/j.jormas.2019.04.008 
A. Debelmas a, , S. Ketoff a, S. Lanciaux a, P. Corre b, M. Friess c, R.H. Khonsari d
a Assistance publique – Hôpitaux de Paris, Hôpital Pitié-Salpêtrière, service de chirurgie maxillo-faciale et stomatologie, Université Pierre et Marie Curie, Sorbonne Universités, 75013 Paris, France 
b Service de stomatologie et chirurgie maxillofaciale, Centre Hospitalier Universitaire, Nantes, faculté de médecine, Université de Nantes, France 
c Département hommes, nature, sociétés, muséum national d'Histoire naturelle, CNRS UMR-7206, Paris, France 
d Assistance publique, Hôpitaux de Paris, Hôpital Necker, enfants malades, service de chirurgie maxillo-faciale et plastique, centre de référence des fentes et malformations faciales (MAFACE), Université Paris Descartes, Université Sorbonne Paris Cité, 75013, Paris, France 

Corresponding author at: Oral and maxillofacial surgery department, Pitié-Salpêtrière University Hospital, 47, boulevard de l’hôpital, 75013, Paris, France.Oral and maxillofacial surgery department, Pitié-Salpêtrière University Hospital47, boulevard de l’hôpitalParis75013France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 5
Iconografías 3
Vídeos 0
Otros 0

Abstract

Introduction

Cephalometry performed on sagittal teleradiographic X-rays is commonly used for the planification of orthognathic procedures. Tomographic imaging techniques (computer tomography or cone-beam computer tomography) are more and more prescribed for the assessment of complex occlusofacial anomalies. In this study, we intended to evaluate if teleradiographic X-rays reconstructed from computer tomography (CT) can be used to trace reliable cephalometric analyses. We assessed the inter- and intra-observer reproducibility of a simplified Delaire analysis (Top 12), one of the numerous common cephalometric analyses, performed with the Delaire Evolution software on three sets of X-rays: (1) conventional cephalometric X-rays, (2) 2D reconstructions obtained from the CT scans of the same patients and (3) 2D reconstructions obtained from CT scans of dry skulls without a cervical spine (anthropological material). Our primary goal was to assess X-rays reconstructed from tomographies as an alternative for conventional cephalometric X-rays. Our secondary goal was to assess whether computerized cephalometric analysis was a reproducible technique, both on clinical and anthropological material.

Materials and methods

We included 10 consecutive adult patients admitted for orthodontic assessment who had benefited from both lateral cephalometric X-rays and from CT-scans. We also included 10 CT-scans from adult dry skulls without a cervical spine, from the collections of the Muséum National d’Histoire Naturelle (Musée de l’Homme, Paris, France). Cephalometric X-rays were reconstructed from CT-scans of both patients and dry skulls using Carestream® (Carestream Health inc., New York, USA). Simplified Delaire analyses (Top12) were conducted by 2 observers using the Delaire Evolution software (JDel, Nantes, France), on the 3 sets of cephalometric X-rays: (1) 10 standard cephalometric X-rays from the orthodontic patients, (2) 10 reconstructed cephalometric X-rays from the CT scans of the orthodontic patients and (3) 10 reconstructed cephalometric X-rays from the CT scans of the dry skulls. A standard statistical assessment of reproducibility was conducted using correlation coefficients.

Results

We found good inter- and intra-observer reproducibility for standard cephalometric X-rays and reconstructed cephalometric X-rays (Intraclass Correlation Coeficient > 0.75). We did not find any difference for angle measures between the standard cephalometric X-rays and the reconstructed cephalometric X-rays for the group of orthodontic patients (P > 0.05). Delaire cephalometric analysis was not reproducible for cephalometric X-rays without a cervical spine, that is for cephalometric X-rays reconstructed from the CT-scans of dry skulls.

Discussion

Delaire computerized simplified Top12 analysis was reproducible for lateral cephalometric X-rays and for reconstructions obtained from CT scans with similar angle measures for a given patient. This analysis does not seem to be reliable for dry skulls without upper cervical spine. This study uses the example of one particular computerized cephalometric analysis in order to show that cephalometric analyses can be performed on lateral reconstructed cephalometric X-rays obtained from CT scans.

El texto completo de este artículo está disponible en PDF.

Keywords : Delaire cephalometric analysis, Intentional cranial deformations, Cephalometric X-rays, Tomography, Reproducibility


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 121 - N° 1

P. 35-39 - février 2020 Regresar al número
Artículo precedente Artículo precedente
  • Intra-articular injection of a mixture of hyaluronic acid and corticosteroid versus arthrocentesis in TMJ internal derangement
  • H.A.M. Marzook, A.A. Abdel Razek, E.A. Yousef, A.A.M.M. Attia
| Artículo siguiente Artículo siguiente
  • Medication-related osteonecrosis of the jaw. Implant presence-triggered osteonecrosis: Case series and literature review
  • M.F. Escobedo, J.L. Cobo, S. Junquera, J. Milla, S. Olay, L.M. Junquera

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.