The effect of loop size on loop security and elongation of a knot - 30/01/20

Doi : 10.1016/j.otsr.2019.10.008 
Selim Ergün , Umut Akgün, Mustafa Karahan
 Acibadem Mehmet Ali Aydinlar University, School of Medicine, Department of Orthopedics and Traumatology, Istanbul, Turkey 

Corresponding author at: Acibadem Kozyatagı Hastanesi, Okur sokak, no: 24, Kozyatağı, 34734, Istanbul.Acibadem Kozyatagı HastanesiOkur sokak, no: 24Kozyatağı34734Istanbul

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

While repairing a teared rotator cuff tendon with suture anchors and horizontal mattress suture configurations, knots should be secure at time zero while approximating the tendon to the bone, otherwise any failure in loop security may cause undesired clinical results. Optimum distance between suture limbs passed through the tendon, in other words the bite size, is still not clear in the literature. The aim of this study was to test the effect of loop size, which is directly related to the bite size, on loop security and elongation of a knot.

Hypothesis

We hypothesized that a knot with a smaller loop size would be more secure. We asked if a knot with shorter circumference (1) would offer a better knot security; (2) would produce less elongation following repeated traction cycles.

Material and methods

Two parallel metal rods in 3.0mm diameter were fixed to load cells of dynamic testing machine. Four groups, from A to D, had the initial rod to rod distances of 2-4-6-8mm respectively (n=10). Surgeon's knots were prepared with 2/0 Ultrabraid® sutures around the rods. A tension meter was used for tying each half hitch under equal tension. Crosshead distances were recorded after 7N pre-load and subsequent 1000 repetitive cyclic loads between 7-30N.

Results

Elongations after a 7N preload for groups A to D were 0.107mm (±0.006), 0.143mm (±0.018), 0,16mm (±0.025), 0.185mm (±0.018) respectively. This increase was significant (p<0.05, power>0.95) between each group except between groups B and C. Maximum elongations after 1000th cycle for groups A to D were 0.32mm (±0.124), 1.12mm (±0.333), 1.162mm (±0.211), 1.292mm (±0.241) respectively. Only samples in group A (0.732mm±0.124) elongated significantly less than others (p<0.05, power >0.95). No knots unravelled or ruptured.

Discussion

This study basically reports that a knot with a shorter loop circumference has superior properties regarding loop security and resistance to elongation. From the perspective of clinical importance, shorter distance between suture limbs of mattress configuration may provide a more secure fixation of the rotator cuff tendon to the bone.

Level of evidence

II.

El texto completo de este artículo está disponible en PDF.

Keywords : Loop circumference, Mattress configuration, Loop security, Maximal elongation


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 1

P. 35-38 - février 2020 Regresar al número
Artículo precedente Artículo precedente
  • Assessment of the Quality and Reliability of the Information on Rotator Cuff Repair on YouTube
  • Haluk Celik, Omer Polat, Cagri Ozcan, Savas Camur, Bekir Eray Kilinc, Metin Uzun
| Artículo siguiente Artículo siguiente
  • 3D motion analysis of latissimus dorsi tendon transfer in patients with posterosuperior rotator cuff tears: Analysis of proprioception and the ability to perform ADLS
  • Pit Hetto, Sarah Erhard, Mirjam Thielen, Sebastian I. Wolf, Felix Zeifang, Stefan van Drongelen, Michael W. Maier

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.