Suscribirse

How is the outcome of the Limb Preservation System™ for reconstruction of hip and knee? - 25/04/20

Doi : 10.1016/j.otsr.2019.09.030 
Maria Anna Smolle , Joerg Friesenbichler, Marko Bergovec, Magdalena Gilg, Werner Maurer-Ertl, Andreas Leithner
 Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036 Graz, Austria 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Despite tremendous advantages in the development and application of megaprostheses in tumour and revision surgery, complications are still not infrequently observed. Only two studies investigating the outcome of the LPS™ system in the proximal femur and distal femur/proximal tibia have been published thus far. Herein, mid-term implant survival rates one of the largest cohort of patients treated with the LPS™-system are presented aiming tp answer: 1) How is the outcome of the LPS™ system in the proximal femur and distal femur/proximal tibia? 2) Which factors are associated with altered implant survival? 3) What is the cumulative risk of complications according to Henderson?

Hypothesis

The LPS™-system is associated with high complication rates that depend on implant site, with infections being most common.

Patients and methods

Fifty-seven patients who received the LPS™-system at the proximal femur (n=31), distal femur (n=21) and proximal tibia (n=5) between 2004 and 2010 for oncological (n=40) or non-oncological (n=17) causes, were retrospectively included. Median follow-up was 5.0 years (range, 0-12.4 years). Complications were classified according to Henderson into instability/soft tissue failure (type 1), aseptic loosening (type 2), structural failure (type 3), periprosthetic infection (type 4), tumour progression (type 5). Competing-risk-analyses were applied to estimate implant survival with death as the competing event.

Results

Twenty-six patients (45.6%) developed a complication, of whom 9 (29.0%) had a proximal femoral and 17 (65.4%) a distal femoral/proximal tibial implant. Type 4 complications were most common (n=11), followed by type 3 (n=6, including 2 yoke-fractures), type 1 and 2 (n=4 each), and type 5 (n=1). The only factor associated with the development of complications in the multivariate model was a distal femoral/proximal tibial implant (hazard-ratio: 7.418, 95% confidence-interval: 2.193-26.096, p=0.001), irrespective of reason for reconstruction and use of muscular flaps. The cumulative-incidence of failure including all complications was 34.3%, 40.7% and 67.1% at 3, 5 and 10 years, respectively.

Discussion

The LPS™-system may be used for proximal femoral reconstructions both in the oncological and non-oncological setting. Rates of complications are higher in our cohort than reported in literature for other, comparable, megaprosthesis systems. Especially in the distal femur/proximal tibia, complication rates were high, partially attributable to the former implant design leading to fractures of the yoke-mechanism. As the implant has been remodelled after these issues became evident, there is no objection to use this megaprosthesis system today.

Level of evidence

IV, Observational Study.

El texto completo de este artículo está disponible en PDF.

Keywords : Tumour endoprosthesis, Reconstruction, LPS™ system, Implant survival


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 3

P. 409-415 - mai 2020 Regresar al número
Artículo precedente Artículo precedente
  • Survival and complications in hinged knee reconstruction prostheses after distal femoral or proximal tibial tumor resection: A retrospective study of 161 cases
  • Matthieu Mazaleyrat, Louis-Romée Le Nail, Guillaume Auberger, David Biau, Philippe Rosset, Denis Waast, François Gouin, Paul Bonnevialle, Matthieu Ehlinger, Gilles Pasquier, Gualter Vaz, French Society of Orthopedic Surgery, Traumatology (SoFCOT)
| Artículo siguiente Artículo siguiente
  • Role of intra-wound powdered vancomycin in primary total knee arthroplasty
  • Xinxian Xu, Xue Zhang, Yu Zhang, Chengwang Chen, Huachen Yu, Enxing Xue

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.