Intraoperative use of cortical step sign and diameter difference sign: Accuracy, inter-rater agreement and influence of surgical experience in subtrochanteric transverse fractures - 08/06/20

Doi : 10.1016/j.otsr.2020.01.015 
Nikolaus Degen a, , Eduardo Suero a, Miriam Bogusch a, Carl Neuerburg a, Kirsi Marjaana Manz b, Christopher A. Becker a, Nima Befrui a, Christian Kammerlander a, Wolfgang Böcker a, Christian Zeckey a
a Department of General, Trauma and Reconstructive Surgery, University Hospital, LMU Munich, Marchioninistr, 15, 81377 Munich, Germany 
b Institute for Medical Information Processing, Biometry and Epidemiology (IBE), LMU Munich, Munich, Germany 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

The cortical step sign (CSS) and diameter difference sign (DDS) are radiographic tools for torsional alignment control in intramedullary nailing. They have been found to be highly relevant in objective radiographic measurements, but for intraoperative visual identification they lack sufficient evidence yet. The aim of this experimental study was to evaluate their (1) accuracy, (2) inter-rater agreement, (3) predictors of correct identification for clinically relevant maltorsion (CRM: ≥15°), and (4) positive and negative predictive values.

Hypothesis

Sensitivity and specificity of CSS and DDS in visual identification of CRM are comparable to those in objective measurement.

Material and methods

Six observers of three different levels of surgical experience evaluated 50 a.p. and 50 lateral views of subtrochanteric fractures of cadaveric specimens with internal/external maltorsion from 0° to 30° to assess for CSS, DDS, and CRM. (1) Sensitivity and specificity were evaluated. Percentage agreement and Cohen's Kappa were used to evaluate accuracy as agreement with measured/true values and (2) inter-rater agreement. To determine (3) significant predictors of correct identification of the CSS, DDS, and CRM, a mixed-effects logistic model was constructed, and (4) predictive values were calculated.

Results

(1) Sensitivities of CSS and DDS for CRM (0.99±0.03 and 0.88±0.06) were close to those in objective measurement (1.00 and 0.90). So were specificities (0.25±0.08 and 0.47±0.17 vs. 0.32 and 0.47). Agreement percentage for CSS was high (90–94%, kappa 0.40–0.69), for DDS and CRM it was slightly lower (74–82%, kappa 0.34–0.57 and 62–76%, kappa 0.26–0.49). (2) Inter-rater agreement also showed the highest values for CSS (88–96%, kappa 0.51–0.73) with slightly lower values for DDS (74–84%, kappa 0.36–0.63) and CRM (62–84%, kappa 0.21–0.68). (3) Training level and the magnitude of maltorsion were found the most relevant predictors of a correct identification of CSS/DDS/CRM. (4) DDS showed a higher positive predictive value (73.1%), CSS a higher negative predictive value (93.5%).

Discussion

We found visual identification of CSS and DDS to be almost as accurate as objective measurement in the detection of CRM. Estimation of maltorsion is not sufficiently reliable, but a negative CSS excludes a CRM with high probability. Both signs should be applied by experienced surgeons.

Level of evidence

Level III, experimental setting, non-randomised experimental trial.

El texto completo de este artículo está disponible en PDF.

Keywords : Bone malalignment, Intramedullary nailing, Femoral fractures, Hip fractures, Torsion abnormality


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 4

P. 639-644 - juin 2020 Regresar al número
Artículo precedente Artículo precedente
  • Fast-track care for pertrochanteric hip fracture: What impact on function and autonomy after discharge?
  • Mathurin Gomez, Louis Rony, Clément Marc, Abdelhafid Talha, Nicolas Ruiz, Sophie Noublanche, André Gillibert, Sara Bergman, Vincent Maynard, Laurent Hubert
| Artículo siguiente Artículo siguiente
  • Total hip arthroplasty with exclusive use of dual-mobility cup after failure of internal fixation in trochanteric fracture
  • Henri Favreau, Matthieu Ehlinger, Philippe Adam, François Bonnomet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.