Suscribirse

La fréquence des scans du capteur de glucose FreeStyle Libre réalisés par le patient diabétique au quotidien est associée à de meilleurs paramètres de suivi de son profil glucosé : analyse de 312 millions d’heures de suivi en vraie vie en France - 12/11/20

The frequency of FreeStyle Libre glucose sensor scans performed by the diabetic patient on a daily basis is associated with better parameters for monitoring his glucose profile: Analysis of 312 million hours of monitoring in real life in France

Doi : 10.1016/j.mmm.2020.08.001 
Jean-Pierre Riveline 1, , Bruno Guerci 2, Anne Wojtusciszyn 3, 4, Timothy C. Dunn 5
1 Assistance publique–Hôpitaux de Paris (AP–HP), université Paris Diderot-Paris VII, hôpital Lariboisière, centre de recherches des Cordeliers, service de diabétologie et d’endocrinologie, Paris, unité Inserm U1138 Immunity and Metabolism in Diabetes, ImMeDiab Team, Paris, France 
2 CHRU de Nancy, hôpital Brabois Adultes, université de Lorraine, service d’endocrinologie, diabétologie et nutrition, Vandœuvre-lès-Nancy, France 
3 Centre hospitalier universitaire vaudois (CHUV), université de Lausanne, service d’endocrinologie, diabétologie et métabolisme, Lausanne, Suisse 
4 CHU de Montpellier, hôpital Lapeyronie, département d’endocrinologie-diabétologie-nutrition, Montpellier, France 
5 Abbott Laboratories, Research and Development, Alameda, California, États-Unis 

Jean-Pierre Riveline, Hôpital Lariboisière, service de diabétologie et d’endocrinologie, 2, rue Ambroise-Paré, 75010 Paris, France.Hôpital Lariboisière, service de diabétologie et d’endocrinologie2, rue Ambroise-ParéParis75010France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 9
Iconografías 7
Vídeos 0
Otros 0

Résumé

Le FreeStyle Libre est un système de mesure continue à la demande, largement utilisé chez les patients avec diabète traité par insulinothérapie optimisée. Cette étude observationnelle évalue l’efficacité métabolique en fonction de la fréquence des scans du FreeStyle Libre.

Méthode

Les résultats des mesures de glucose ont été anonymisés et téléchargés dans une base de données. Les mesures de 20 960 patients entre septembre 2014 et juin 2017, et de 97 788 patients entre septembre 2014 et septembre 2018, ont été analysées à partir de 1 068 269 capteurs qui ont fourni 1,25 milliard de valeurs de glucose enregistrées automatiquement toutes les 15minutes. Les sujets ont été classés selon la fréquence de scan. Les paramètres de glucose ont été calculés pour chaque groupe, notamment l’HbA1c estimée, le pourcentage de temps au-dessus, au-dessous, et dans la cible (TIR) correspondant à une valeur située entre 70 et 180mg/dL.

Résultats

La fréquence moyenne des scans par jour était de 10. Lorsque cette fréquence passait de 3 à 14, la réduction de l’HbA1c estimée était de 0,8 %. Le TIR 70–180 augmentait de +9 % pour une fréquence de 3 à 14 scans/j alors que le gain était de +5 % au-delà de cette fréquence. Les T<70, T<55, T<45mg/dL augmentaient entre une fréquence de scan entre 4/j et 8/j de 1,1 %. Au-delà de 8 scans/jour, ces temps diminuaient avec la fréquence des scans.

Conclusion

Cette étude confirme que la fréquence des scans du FreeStyle Libre est associée à une amélioration du contrôle métabolique, y compris du TIR et du temps passé en hypoglycémie, et ceci même au-delà de 14 scans par jour.

El texto completo de este artículo está disponible en PDF.

Summary

The FreeStyle Libre is an on-demand continuous measurement system, widely used in patients with diabetes treated with optimized insulin therapy. This observational study evaluates the metabolic benefits as a function of the frequency of FreeStyle Libre scans.

Method

Glucose scans results were anonymized and uploaded to a database as the meters were connected to a computer connected to the Internet. Data from 20,960 patients between September 2014 and June 2017 and 97,788 patients between September 2014 and September 2018 were analyzed from 1,068,269 sensors that provided 141 million glucose values and 1.25 billion automatically recorded glucose values every 15minutes. Each subject was classified according to scan frequency. Glucose parameters were calculated for each group, including estimated HbA1c, with the percentage of time above (T>), below (T<) and in target (TIR) corresponding to a value between 70 and 180mg/dL.

Results

The average frequency of scans per day was 10. When this frequency was increased from 3 to 14, the estimated reduction in HbA1c was 0.8%. The TIR 70–180 increased by +9% for a frequency of 3 to 14 scans per day while the gain was a further +5% beyond this frequency. T<70, T<55, T<45mg/dL increased between a scan frequency of<4/day and 8/day by 1.1%. Beyond 8 scans/day, these times decreased with the frequency of scans.

Conclusion

This study confirms that the frequency of FreeStyle Libre scans is associated with improved metabolic control, including TIR and time spent in hypoglycemia.

El texto completo de este artículo está disponible en PDF.

Mots clés : Diabète, FreeStyle Libre, Surveillance glycémique, Données de vraie vie, France

Keywords : Diabetes, FreeStyle Libre, Blood glucose monitoring, Real life data, France


Esquema


© 2020  The Author(s). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 14 - N° 7

P. 585-593 - novembre 2020 Regresar al número
Artículo precedente Artículo precedente
  • Le capteur de glucose en vraie vie
  • Sylvie Picard
| Artículo siguiente Artículo siguiente
  • Intérêt du capteur de glucose en continu FreeStyle Libre Pro dans la prise en charge du diabète de type 2 : partage d’expérience
  • Jocelyne MBemba

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.