Suscribirse

Accuracy of static digital surgical guides for dental implants based on the guide system: A systematic review - 11/12/20

Doi : 10.1016/j.jormas.2020.10.010 
R. Eftekhar Ashtiani a, Z. Ghasemi b, , M. Nami b, F. Mighani b, M. Namdari c, d
a Department of Dental Technology, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran 
b School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran 
c Community Oral Health Department, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran 
d Department of Biostatistics, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran 

Corresponding author.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Friday 11 December 2020
This article has been published in an issue click here to access

Abstract

In the present study, we tried to review the current literature, focusing on the effect of different guide systems on the accuracy of the digital surgical guides.

A search in PubMed’s database, without any date restriction, was performed using keywords based on the PICO question. 54 of the 2378 articles’ were chosen for full-text assessment. Articles were screened using predetermined inclusion and exclusion criteria. 21 articles were included in the qualitative assessment. Descriptive analysis was performed for numeric parameters using mean ± standard deviation. Six types of guide systems were used in the included articles. The commonest guide system was SimPlant (45.64%) followed by NobleGuide (23.00%). The pooled mean angle deviation, global coronal deviation, and global apical deviation were 3.43 mm (95% CI = 2.96, 3.90), 1.16 mm (95% CI = 0.98, 1.24) and 1.35 mm (95% CI = 1.11, 1.59), respectively. The maximum mean(SD) of angle deviation, global coronal deviation, and global apical deviation happened in Stent Cad 4.1(1.86) degrees, NobleGuide 1.86(0.56) mm, and OnDemend3d 1.56(1.48) mm, respectively.

Although a final statement could not be made on which system is better, it is certain that the software affects the deviation and could be as important as the implant itself.

Clinical significance

The choice of guide systems used for the production of static guide systems which was studied in this article could affect the accuracy of the implant placement procedure.

El texto completo de este artículo está disponible en PDF.

Keywords : Static surgical guide, Digital surgical guide, Implant guide system, Accuracy, Dental implants, Systematic review


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.