Gestion des doses liées à l’imagerie de positionnement en radiothérapie - 01/01/21

Management of image guidance doses delivered during radiotherapy

Doi : 10.1016/j.canrad.2020.05.023 
G. Delpon a, , D. Lazaro b, R. de Crevoisier c
a Service de physique médicale, institut de cancérologie de l’Ouest, boulevard Jacques-Monod, 44805 Nantes Saint-Herblain, France 
b Laboratoire modélisation et simulation des systèmes, CEA-LIST, Saclay, France 
c Service de radiothérapie, Centre Eugène Marquis, Rennes, France 

*Auteur correspondant.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Friday 01 January 2021
This article has been published in an issue click here to access

Résumé

La radiothérapie guidée par l’image est devenue une technique standard d’irradiation permettant d’améliorer le devenir clinique des patients en termes de toxicité et de contrôle local du fait d’un meilleur ciblage du rayonnement lors de la séance d’irradiation. Les systèmes d’imagerie de positionnement, embarqués ou non, tels que les kV pour les acquisitions bidimensionnelles et surtout les tomographies coniques de basse énergie pour les acquisitions tridimensionnelles sont cependant irradiants dans un large volume comprenant le volume cible mais aussi du tissu sain, avec un risque théorique de majoration de toxicité et de second cancer. Il apparaît donc très important à la fois d’optimiser la dose délivrée par l’imagerie de contrôle de type tomographies coniques de basse énergie mais aussi de rapporter cette dose. Le rapport de l’AAPM (Association of Physicists in Medicine) publié en 2018 (« Image guidance doses delivered during radiotherapy : Quantification, management, and reduction ») propose une démarche d’optimisation et de gestion de ces doses. Ce rapport constitue la base de cette mise au point dont les objectifs sont de donner les ordres de grandeur des doses délivrées par l’imagerie de positionnement et de proposer une méthodologie de gestion de ces doses dans la pratique clinique. Une tomographie conique de basse énergie délivre approximativement 0,5 à 2 cGy à l’isocentre selon la localisation anatomique. Tant que les algorithmes de calcul ne sont pas disponibles dans les systèmes de planimétrie pour les faisceaux de positionnement, il semble adapté d’utiliser au moins les ordres de grandeur publiés. Cette estimation doit permettre au clinicien de décider de la stratégie thérapeutique en cas d’accumulation de sessions d’imagerie de positionnement.

El texto completo de este artículo está disponible en PDF.

Abstract

Image-guided radiotherapy (IGRT) has become a standard irradiation technique to improve the clinical outcome of patients in terms of toxicity and local control due to better targeting of radiation during the irradiation fraction. Positioning imaging systems, whether embedded or not, such as kV for 2×2D acquisitions and especially kVCBCT for 3D acquisitions are however irradiating in a large volume including the target volume but also healthy tissue, with a theoretical risk of increased toxicity and second cancer. It therefore appears very important both to optimize the absorbed dose due to IGRT practice but also to report it, especially in case of kVCBCT. The AAPM report published in 2018 (« Image guidance doses delivered during radiotherapy: Quantification, management, and reduction ») proposes a management of image guidance doses delivered during radiotherapy. This report is the basis of this focus article that aims at giving orders of magnitude and proposing a management of image guidance doses delivered during radiotherapy in clinical practice. The dose delivered per kVCBCT is about 0.5 to 2 cGy at isocenter according to treatment site. As long as the calculation algorithms are not available in the treatment planning systems, it seems appropriate to use at least the published dose orders of magnitude. This estimate should ultimately allow the clinician to decide on the therapeutic strategy in the event of accumulation of positioning imaging sessions.

El texto completo de este artículo está disponible en PDF.

Mots clés : Radiothérapie guidée par l’image, Positionnement, Dose

Keywords : IGRT, Setup, Dose


Esquema


© 2020  Société française de radiothérapie oncologique (SFRO). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.