Suscribirse

Quantification of diffuse myocardial fibrosis using CMR extracellular volume fraction and serum biomarkers of collagen turnover with histologic quantification as standard of reference - 25/02/21

Doi : 10.1016/j.diii.2020.07.005 
C. Foussier a, b, 1, P.A. Barral a, b, 1, M. Jerosh-Herold c, V. Gariboldi d, S. Rapacchi b, A. Gallon a, A. Bartoli a, Z. Bentatou b, M. Guye b, M. Bernard b, e, A. Jacquier a, b,
a Department of Radiology, Hôpital de la Timone, 13385 Marseille, France 
b UMR CNRS 7339, Aix-Marseille University, 13385 Marseille, France; Centre de Résonance Magnétique Biologique et Médicale, Hôpital de la Timone, AP-HM, 13385 Marseille cedex 05, France 
c Non-Invasive Cardiovascular Imaging Section, Brigham and Women's Hospital, Boston, MA 02215, USA 
d Department of Heart Surgery, Hôpital de la Timone, 13385 Marseille cedex 05, France 
e Aix-Marseille Univ, CNRS, CRMBM, 13000 Marseille, France 

Corresponding author. Department of Heart Surgery, Hôpital de la Timone, 13385 Marseille cedex 05, France.Department of Heart Surgery, Hôpital de la TimoneMarseille cedex 0513385France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

Basal anteroseptal ECV derived from CMR correlates significantly with the magnitude of diffuse interstitial myocardial fibrosis measured on histopathological samples taken from patients undergoing valve surgery.
Basal anteroseptal ECV strongly correlates with global ECV.
Global ECV poorly correlates with TIMP-1 and MMP-2 which are known serum biomarkers of collagen turnover.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

To compare the assessment of diffuse interstitial myocardial fibrosis in valvular diseases using cardiac magnetic resonance (CMR) extracellular volume fraction (ECV) quantification and serum biomarkers of collagen turnover using results of myocardial biopsy as standard of reference.

Materials and methods

This prospective monocentric study included consecutive patients before aortic valvular replacement. All patients underwent: i), 1.5T CMR with pre and post contrast T1 mapping sequence and ECV computation; ii), serum quantification of matrix metalloproteinases (MMPs) and tissue inhibitor of metalloproteinases (TIMPs) and iii), myocardial biopsies were collected during surgery to assess collagen volume fraction (CVF). Patients with coronary artery disease were excluded. Correlation between native T1, ECV, CVF and serum biomarkers were assessed using Pearson correlation test. Agreement between basal anteroseptal ECV with global ECV was assessed using Bland-Altman test.

Results

Twenty-one patients, 16 with aortic stenosis and 5 with aortic regurgitation were included. There were 12 men and 9 women with a mean age of 74.1±6.8 (SD) years (range: 32–84 years). Mean global ECV value was 26.7±2.7 (SD) % (range: 23.4–32.5%) and mean CVF value was 12.4±9.7% (range: 3.2–25.7%). ECV assessed at the basal anteroseptal segment correlated moderately with CVF (r=0.6; P=0.0026). There was a strong correlation and agreement between basal anteroseptal ECV and global ECV, (r=0.8; P<0.0001; bias 5.4±6.1%) but no correlation between global ECV and CVF (r=0.5; P=0.10). Global ECV poorly correlated with serum TIMP-1 (r=0.4; P=0.037) and MMP-2 (r=0.4; P=0.047). No correlation was found between serum biomarkers and basal anteroseptal- ECV or native T1.

Conclusion

In patients with severe aortic valvulopathy, diffuse myocardial fibrosis assessed by anterosepto-basal ECV correlates with histological myocardial fibrosis. Anteroseptobasal ECV strongly correlates with global ECV, which poorly correlates with TIMP-1 and MMP-2, serum biomarkers involved in the progression of heart failure.

El texto completo de este artículo está disponible en PDF.

Keywords : Cardiac magnetic resonance imaging, Aortic valve stenosis, Myocardial fibrosis, Extracellular volume fraction, T1 mapping

Abbreviations : AR, AS, CITP, CMR, CVF, ECV, EDV, ESV, ICC, LGE, LVEF, MMPs, MMP-2, MOLLI, NYHA, PICP, PIIINP, ROI, SD, TIMP-1


Esquema


© 2020  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 102 - N° 3

P. 163-169 - mars 2021 Regresar al número
Artículo precedente Artículo precedente
  • Myocardial deformation assessment in patients with precapillary pulmonary hypertension: A cardiac magnetic resonance study
  • A. Kallifatidis, S.-A. Mouratoglou, G. Giannakoulas, S. Finitsis, H. Karvounis, G. Sianos
| Artículo siguiente Artículo siguiente
  • Diagnostic performance of sacroiliac joint MRI and added value of spine MRI to detect active spondyloarthritis
  • M. Plier, A. Nzeusseu Toukap, N. Michoux, M.S. Stoenoiu, T. Kirchgesner, P. Durez, B. Lauwerys, F.E. Lecouvet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.