Suscribirse

Évaluation du circuit des dispositifs médicaux stériles et implantables au Centre Hospitalier de Laval : cartographie des risques et mise en place d’actions correctives - 13/03/21

Evaluation of the circuit of sterile and implantable medical devices at the hospital center of Laval: Risk mapping and implementation of corrective actions

Doi : 10.1016/j.phclin.2020.10.002 
Pauline Rault 1, , Nathalie Naturel 1, Elisabeth Bedouet 1, Céline-Marie Delafontaine 2, Catherine Gilmas 3, Liliane Zbierski 1, Françoise Lecomte 1
1 Centre Hospitalier de Laval, Pharmacie, 33 rue du Haut-Rocher, 53000 Laval, France 
2 Centre Hospitalier de Laval, qualité-gestion des risques, Laval, France 
3 Centre Hospitalier de Laval, direction des soins, Laval, France 

Pauline Rault, Centre Hospitalier de Laval, 33 rue du Haut-Rocher, 53000 Laval, France.Centre Hospitalier de Laval33 rue du Haut-RocherLaval53000France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 9
Iconografías 5
Vídeos 0
Otros 0

Résumé

Introduction

Le circuit des dispositifs médicaux stériles et implantables (DMS/DMI) est complexe et peut entraîner des évènements indésirables associés aux soins. L’objectif de ce travail est d’évaluer puis d’optimiser la sécurisation de ce circuit dans notre établissement.

Matériels et méthodes

La grille InterDiag DMS® V2.0 de l’Agence Nationale d’Appui à la Performance a été choisie. Elle comprend deux modules évaluant le circuit des DMS, des DMI et les DMS utilisés dans cinq pratiques de soins. Les audits des unités de soins (US) et de la pharmacie (PUI) ont été réalisés entre novembre 2019 et février 2020.

Résultats

Dix-neuf US dont la PUI ont été auditées. Les taux de maîtrise globaux des différents items évoluent entre 62 et 74 %. Les étapes ayant les taux de maîtrise les plus faibles sont la demande (PUI : 50 %), le transport (PUI : 46 %), le stockage (US : 44 %) et l’évaluation de la traçabilité des DMI (PUI : 45 %). Parmi les 45 actions de sécurisation formulées, 16 ont été mises en place comme la réalisation d’audits sur la traçabilité des DMI.

Dicussion et conclusion

La cartographie effectuée de façon multidisciplinaire montre une bonne maîtrise globale du circuit. Les étapes les plus à risques identifiées sont en cours de sécurisation. Le plan d’action formulé devra être suivi et actualisé chaque année.

El texto completo de este artículo está disponible en PDF.

Summary

Introduction

The circuit of sterile and implantable medical devices (MD) is complex and can lead to adverse events associated with care. The objective of this work is to assess and then optimize the security of this circuit in our establishment.

Materials and methods

The InterDiag ® V2.0 grid from the Agence Nationale d’Appui à la Performance was chosen. It includes two modules evaluating the circuit of sterile MD, implantable MD and sterile MD used in five health care practices. The care unit (CU) and pharmacy audits were carried out between November 2019 and February 2020.

Results

Nineteen CU including the pharmacy were audited. The overall mastery rates for the various items vary between 62 and 74%. The stages with the lowest control rates are demand (pharmacy: 50%), transport (pharmacy: 46%), storage (CU: 44%) and evaluation of the traceability of implantable MD (pharmacy: 45%). Among the 45 security actions formulated, 16 have been implemented as audits of the traceability of implantable MD.

Discussion and conclusion

The cartography carried out in a multidisciplinary way shows a good control of the circuit. The most risky stages identified are in the process of being secured. The formulated action plan will have to be monitored and updated every year.

El texto completo de este artículo está disponible en PDF.

Mots clés : Audit, Circuit, Dispositifs médicaux stériles et implantables

Keywords : Audit, Circuit, Medical devices


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 56 - N° 1

P. 75-83 - mars 2021 Regresar al número
Artículo precedente Artículo precedente
  • Rôles et impacts des pharmaciens en Belgique : une revue de littérature exploratoire
  • Corentin Frison, Geneviève Philippe, Els Mehuys, Koen Boussery, Jean-François Bussières
| Artículo siguiente Artículo siguiente
  • What is the efficacy of BCG vaccination in the protection from COVID-19 in European countries?
  • K. Ghazvini, M. Keikha

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.