Suscribirse

MRI diagnosis of saccular hydrops: Comparison of heavily-T2 FIESTA-C and 3D-FLAIR sequences with delayed acquisition - 14/05/21

Doi : 10.1016/j.neurad.2019.04.005 
Michael Eliezer a, , Guillaume Poillon a, Julien Horion a, Phillipe Lelion b, Emmanuel Gerardin a, Nicolas Magne a, André Gillibert c, Arnaud Attyé a, d
a Department of Neuroradiology and MRI, Rouen University Hospital, Rouen, France 
b Department of Head and Neck Surgery, Rouen University Hospital, Rouen, France 
c Department of Biostatistics, Rouen University Hospital, Rouen, France 
d Department of Neuroradiology and MRI, Grenoble Alpes University Hospital – SFR RMN Neurosciences, Grenoble, France 

Corresponding author. Neuroradiology and MRI Unit, Rouen University Hospital, 76000 Rouen, France.Neuroradiology and MRI Unit, Rouen University HospitalRouen76000France
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Friday 14 May 2021
This article has been published in an issue click here to access

Abstract

Purpose

Currently, 3D-FLAIR sequence performed 4hours after the intravenous administration of a single dose of contrast media is the imaging technique of choice for the diagnosis of saccular hydrops (SH). Recently, the diagnosis of SH has also been reported with heavily-T2 weighted sequences.

Materials and methods

In this retrospective imaging study, we performed 3D-FLAIR sequences 4hours after contrast media administration and 3D FIESTA-C sequences before and 4hours after contrast media administration in 30 patients with unilateral definite, probable or possible clinical diagnosis of Menière's disease (MD). Two radiologists, blinded to the clinical data, independently assessed the presence of saccular hydrops. Inter-reader agreement tests were performed.

Results

On delayed post-contrast 3D-FLAIR sequence, 15 patients out of 30 referred with a SH that was never seen on the controlateral asymptomatic side. The specificity and the sensitivity to detect MD side were 100% and 50% respectively. On non-enhanced 3D FIESTA-C sequence, 16 patients out of 30 (53%) referred with a saccular hydrops that was observed in 6 patients on the clinical asymptomatic ear. The specificity and the sensitivity to detect MD side were 80% and 33% respectively. On delayed 3D FIESTA-C sequence, 13 patients out of 30 (43%) referred with a saccular hydrops that was seen in 4 patients on the controlateral asymptomatic side. The specificity and the sensitivity to detect MD side were 83% and 27% respectively.

Conclusion

Delayed post-contrast 3D-FLAIR is highly specific of MD symptoms while 3D FIESTA-C sequences are less sensitive and specific for the diagnosis of SH.

El texto completo de este artículo está disponible en PDF.

Keywords : Endolymphatic hydrops, Menière's disease, MRI


Esquema


© 2019  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.