Suscribirse

Diffusion-Weighted-Imaging infarct volume measurement tools show discrepancies leading to diverging thrombectomy decisions - 03/06/21

Doi : 10.1016/j.neurad.2020.03.002 
Naim Khoury a, Cyril Dargazanli b, Kevin Zuber c, Stanislas Smajda c, Marie Bitar d, Grégoire Boulouis e, Wagih Ben Hassen e, Claire Ancelet f, Célina Ducroux c, Robert Fahed c, g,
a HSHS Neuroscience Center, HSHS St. John's Hospital, Springfield, IL, USA 
b Interventional Neuroradiology Department, hôpital-Gui-de-Chauliac, Montpellier, France 
c Interventional Neuroradiology Department, Fondation Ophtalmologique Adolphe de-Rothschild-Hospital, 29, rue Manin, 75019 Paris, France 
d Radiology Department, centre hospitalier de Jolimont, La Louvière, Belgium 
e Department of Neuroradiology, centre hospitalier Saint-Anne, Paris, France 
f Department of Neuroradiology, centre hospitalier universitaire Bicêtre, Le Kremlin-Bicêtre, France 
g Department of Medicine, Division of Neurology, The Ottawa Hospital, Ottawa, Canada 

Corresponding author at: Department of Medicine, Division of Neurology, The Ottawa Hospital, Ottawa, Canada.Department of Medicine, Division of Neurology, The Ottawa HospitalOttawaCanada

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 6
Iconografías 3
Vídeos 0
Otros 0

Graphical abstract




El texto completo de este artículo está disponible en PDF.

Highlights

Available tools for the measurement of DWI infarct show excellent correlation.
Physicians using tools other than RAPID should be aware of potential discrepancies.
These discrepancies might lead to contradictory thrombectomy decisions.

El texto completo de este artículo está disponible en PDF.

Abstract

Background and purpose

Recent clinical trials demonstrated the benefit of thrombectomy beyond 6h based on the automated measurement of infarct volume exclusively with the RAPID software. We aimed to compare eight tools commonly used for the measurement of infarct volume and see whether they would lead to similar thrombectomy decisions based on the Diffusion-weighted-imaging or computerized-tomography-perfusion Assessment with clinical mismatch in the triage of Wake-up and late-presenting strokes undergoing Neurointervention with Trevo (DAWN) trial imaging inclusion criteria.

Materials and Methods

The diffusion-weighted-imaging (DWI) infarct volume of 36 patients was measured with 3 automated tools (including RAPID) and 5 non-automated tools. The agreement for the measurements of DWI infarct volume and the resulting thrombectomy decisions were assessed with intraclass correlation coefficient (ICC) and Fleiss’ Kappa (K) statistics.

Results

The correlation for the measurement of DWI infarct volume between all 9 tools was excellent (ICC>0.8). After dichotomization, agreement was substantial for any of the cut-points used in DAWN trial. Discrepancies involving at least one of the tools for thrombectomy decisions based on DAWN criteria occurred in one third of cases. Compared with RAPID, the use of any other tool for treatment decision based on DAWN criteria would have led to contradictory decisions in 6% to 19% of cases.

Conclusion

There are several currently available tools for the measurement of DWI infarct volume with excellent correlation. Despite the high agreement demonstrated in our study, frequent discrepancies between measurements in some dichotomized configurations led to frequent diverging thrombectomy decisions when applying DAWN criteria.

El texto completo de este artículo está disponible en PDF.

Keywords : Stroke, Volume, RAPID, Thrombectomy


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 48 - N° 4

P. 305-310 - juin 2021 Regresar al número
Artículo precedente Artículo precedente
  • Intra-arterial in-situ bevacizumab injection effect on angiogenesis. Results on a swine angiogenesis model
  • Chrysanthi Papagiannaki, Catherine Yardin, Christina Iosif, Claude Couquet, Frederic Clarençon, Charbel Mounayer
| Artículo siguiente Artículo siguiente
  • Agreement of intracranial vessel diameters measured on 2D and 3D digital subtraction angiography using an automatic windowing algorithm
  • Y. Abe, I. Yuki, K. Otani, T. Shoji, T. Ishibashi, Y. Murayama

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.