Suscribirse

Comparison of the cardio-respiratory response of a training session on cycloergometer or treadmill versus an Adapted Physical Activity session on Nintendo Wii, in patients with chronic respiratory disease - 11/06/21

Doi : 10.1016/j.resmer.2021.100827 
S. Nicolas a, M. Beaumont b, , P.-Y. Glaziou a, B. Simon c, C. Gut-Gobert a, d, F. Couturaud d
a Pulmonary Rehabilitation Unit, University Hospital of Brest, France 
b Pulmonary Rehabilitation Unit, Morlaix Hospital Centre, EA3878 (GETBO) CIC Inserm 1412, European University of Occidental Brittany, Morlaix, France 
c University Hospital of Brest, European University of Occidental Brittany, Brest, France 
d Dept of Internal Medicine and Chest Diseases, EA3878 (GETBO), CIC INSERM 1412, University Hospital of Brest, European University of Occidental Brittany, Brest, France 

Corresponding author at: EA 3878 (GETBO), CIC Inserm 1412, Pulmonary Rehabilitation Unit, Morlaix Hospital Centre, 29600 Morlaix, France.EA 3878 (GETBO), CIC Inserm 1412, Pulmonary Rehabilitation Unit, Morlaix Hospital CentreMorlaix29600France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 7
Iconografías 3
Vídeos 0
Otros 0

Abstract

Objectives

During a pulmonary rehabilitation program (PRP), patients frequently report that the classically proposed activities (as cycloergometer or treadmill) are not playful. The goal of adapted physical activities is to maintain physical activity that is more playful for patients. The Nintendo Wii Gaming Console allows a playful physical activity. However, it seems important to know if this tool allows physical activity with an effective cardiorespiratory effect. The objective was to compare the cardiorespiratory response of a 30-minute training session on cycloergometer (C) and treadmill (T) versus a 30-minute training session with Wii.

Methods

Patients admitted to the PR unit of Brest University Hospital (France) were eligible for this randomized study if they had a chronic pulmonary disease. The endpoints were heart rate (HR), pulse oxymetry, dyspnea, lower limb penibility and pleasure felt.

Results

Twenty patients were prospectively included. HR was significantly higher at the end of the Wii session in comparison with C session (P=0.001); there was no significant difference in HR between Wii and T. We found no significant difference for dyspnea and lower limb penibility between Wii and C (respectively P=0.8 and P=0.7) and between Wii and T (respectively P=0.96 and P=0.5). The pleasure felt was significantly greater during Wii compared to C and T (respectively P=0.001 and P=0.001).

Conclusions

Exercise training using Wii with identifiable games require higher HR at the end of the session compared to C and a similar cardiorespiratory response compared to T with the same dyspnea and lower limb exertion and with a pleasure felt significantly higher. Wii can be used for exercise training during PRP.

El texto completo de este artículo está disponible en PDF.

Keywords : Pulmonary rehabilitation, Chronic lung disease, Physical training, Physical Activity, Dyspnea


Esquema


© 2021  SPLF and Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 79

Artículo 100827- mai 2021 Regresar al número
Artículo precedente Artículo precedente
  • Sampling strategy for bacteriological diagnosis of intrathoracic tuberculosis
  • T. Maitre, V. Ok, F. Morel, I. Bonnet, W. Sougakoff, J. Robert, V. Trosini, E. Caumes, A. Aubry, N. Veziris
| Artículo siguiente Artículo siguiente
  • Daily multidisciplinary COVID-19 meeting: Experiences from a French university hospital
  • C. Rolland-Debord, A. Canellas, P. Choinier, A. Milon, I. Debrix, E. Blin, N. Belaube, S. Mattioni, F. Millet, M. Nadal, C. Petit-Hoang, P. Rigaud, J.S. Rech, M. Siguier, D. Sroussi, M. Denis, C. Amiel, M. Fartoukh, S. Georgin-Lavialle, L. Lassel, A. Parrot, J. Cadranel

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.