Suscribirse

Apport des caméras CZT grand champ 2D et 3D dans l’évolution des pratiques cliniques - 16/07/21

Contribution of 2D and 3D whole-body CZT cameras in the evolution of clinical practice

Doi : 10.1016/j.mednuc.2021.06.135 

Groupe de travail SFPM Caméras CZT grand champ

D. Serre a, K. Doyeux b, , G. Le Rouzic c, C. Barrau d, S. Hapdey e, P. Tylski f, E. Cassol g, L. Imbert h
a CIMOF Service de médecine nucléaire clinique Pasteur, Toulouse, France 
b Service de médecine nucléaire, CHU Bichat, AP–HP, Paris, France 
c Service de médecine nucléaire, Centre Hospitalier Régional d’Orléans, Orléans, France 
d Service de médecine nucléaire, CHU de Nîmes, Nîmes, France 
e Service de médecine nucléaire, Centre Henri Becquerel, Rouen, France 
f Service physique médicale et radioprotection, hospices civils de Lyon, Lyon, France 
g Service de médecine nucléaire, CHU de Toulouse, Toulouse, France 
h Service de médecine nucléaire, hôpital Brabois, CHRU Nancy, Nancy, France 

Auteur correspondant.
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Friday 16 July 2021
This article has been published in an issue click here to access

Résumé

Les caméras CZT grand champ actuellement disponibles présentent soit une configuration géométrique « 2D » (2 détecteurs plans) soit une configuration « 3D » (12 détecteurs répartis sur un anneau de 360°). Elles utilisent une technologie de détecteurs plus performants que les scintillateurs NaI(Tl), notamment en termes de résolution en énergie et de rapport contraste/bruit. L’apport d’une géométrie dite 3D augmente la sensibilité de détection car la distance entre l’objet et le détecteur diminue, permettant ainsi d’améliorer la résolution spatiale en mode tomographique. Par ailleurs, les corrections apportées par les différents algorithmes de reconstruction spécifiques de chacun des systèmes contribuent à améliorer la qualité d’image. L’ensemble de ces performances permettent d’optimiser les protocoles d’examens en diminuant l’activité administrée et/ou la durée d’enregistrement, de réaliser des acquisitions double isotope et de positionner la TEMP dans une stratégie théranostique.

El texto completo de este artículo está disponible en PDF.

Abstract

Current commercially available whole-body CZT cameras have different geometric configurations such as “2D” geometry (2 flat detectors) or “3D” geometry (12 detectors on a 360° ring shaped gantry). These cameras utilize more effective detectors compared to NaI(Tl) scintillators, especially in terms of energy resolution and contrast-to-noise ratio. The contribution of “3D” geometry enables increased detection sensitivity since the distance between the object and detector decreased, thus providing improved tomographic spatial resolution. In addition, corrections provided by dedicated reconstruction algorithms contribute to improved image quality. All these factors allow protocols optimization through the reduction of injected activity and/or recording time, performance of dual isotope studies and the utilization of SPECT within a theranostic strategy.

El texto completo de este artículo está disponible en PDF.

Mots clés : CZT, TEMP/TDM, Qualité image, Performances

Keywords : CZT, SPECT/CT, Image quality, Performances


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.