Absolute cerebral blood flow: Assessment with a novel low-radiation-dose dynamic CT perfusion technique in a swine model - 31/10/21

Doi : 10.1016/j.neurad.2021.09.003 
Pablo Abbona a, Yixiao Zhao a, Logan Hubbard a, Shant Malkasian a, Brooklynn Flynn a, Sabee Molloi a,
a Department of Radiological Sciencesa, University of California, Irvine, Irvine, CA, 92697, United States of America 

Corresponding author at: Department of Radiological Sciences, University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697-5000.Department of Radiological SciencesUniversity of CaliforniaIrvine, Medical Sciences I, B-140IrvineCA92697-5000
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Sunday 31 October 2021
This article has been published in an issue click here to access

Highlights

Validation of a novel low-dose dynamic CT perfusion technique in a swine model using fluorescent microsphere measurement as the reference standard.
Accurate brain perfusion measurement in ml/min/g using a new low-dose dynamic CT perfusion technique.
This technique has the potential for accurate diagnosis and follow up of stroke and vasospasm.

El texto completo de este artículo está disponible en PDF.

Abstract

Rationale and objectives

To validate the accuracy of a novel low-dose dynamic CT perfusion technique in a swine model using fluorescent microsphere measurement as the reference standard.

Materials and methods

Contrast-enhanced dynamic CT perfusion was performed in five swine at baseline and following brain embolization. Reference microspheres and intravenous contrast (370 mg/ml iodine, 1 ml/kg) were injected (5 ml/s), followed by dynamic CT perfusion. Scan parameters were 320×0.5 mm, 100 kVp and 200 mA. On average, 47 contrast-enhanced volume scans were acquired per acquisition to capture the time attenuation curve. For each acquisition, only two systematically selected volume scans were used to quantify brain perfusion with first-pass analysis technique. The first volume scan was selected at the base, simulating bolus tracking, while the second volume at the peak of the time attenuation curve similar to a CT angiogram. Regional low-dose CT perfusion measurements were compared to the microsphere perfusion measurements with t-test, linear regression and Bland-Altman analysis. The radiation dose of the two-volume CT perfusion technique was determined.

Results

Low-dose CT perfusion measurements (PCT) showed excellent correlation with reference microsphere perfusion measurements (PMICRO) by PCT = 1.15 PMICRO - 0.01 (r = 0.93, p ≤ 0.01). The CT dose index and dose-length product for the two-volume CT perfusion technique were 25.6 mGy and 409.6 mGy, respectively.

Conclusions

The accuracy and repeatability of a low-dose dynamic CT perfusion technique was validated in a swine model. This technique has the potential for accurate diagnosis and follow up of stroke and vasospasm.

El texto completo de este artículo está disponible en PDF.

Key Words : Brain, Stroke, Perfusion, Multidetector computed tomography, Models, Animal


Esquema


 Department social media: Twitter @uciradiology
 Non-standard Abbreviations and Acronyms: none.


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.