The effect of a post-scan processing denoising system on image quality and morphometric analysis - 02/12/21

Doi : 10.1016/j.neurad.2021.11.007 
Noriko Kanemaru, MD , Hidemasa Takao, PhD, Shiori Amemiya, PhD, Osamu Abe, PhD #
 Department of Radiology, University of Tokyo, Tokyo, Japan 

Corresponding author: Noriko Kanemaru, Department of Radiology, University of Tokyo, Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan, Telephone: +81-3-5800-8666, Fax: +81-3-5800-8935Department of Radiology, University of TokyoTokyo, 7-3-1 HongoBunkyo-kuTokyo113-8655Japan
En prensa. Manuscrito Aceptado. Disponible en línea desde el Thursday 02 December 2021
This article has been published in an issue click here to access

HighLights

The AI-based denoising system improves image quality while maintaining contrast.
The AI-based denoising system improves reliability in brain morphometric analysis in FreeSurfer.
Improvement is more obvious in longitudinal than cross-sectional analysis.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose: MR image quality and subsequent brain morphometric analysis are inevitably affected by noise. The purpose of this study was to evaluate the effectiveness of an artificial intelligence (AI)-based post-scan processing denoising system, intelligent Quick Magnetic Resonance (iQMR), on MR image quality and brain morphometric analysis.

Methods: We used 1.5T MP-RAGE MR images acquired from the Alzheimer's Disease Neuroimaging Initiative 1 database. The images of 21 subjects were used for cross-sectional analysis and 15 for longitudinal analysis. In the longitudinal analysis, two timepoints over a 2-year interval were used. Each subject was scanned twice at each timepoint. MR images processed with and without the denoising system were compared both visually and objectively using FreeSurfer cortical thickness analysis.

Results: The denoising system reduced the noise with good white–gray matter contrast (noise: p < 0.001; contrast: p = 0.49). The mean intraclass correlation coefficients (ICCs) of cortical thickness were slightly better in the images processed with the denoising system (0.739/0.859/0.883; Gaussian smoothing kernel of full width at half maximum = 0/10/20) compared with the unprocessed images (0.718/0.854/0.880). In the longitudinal analysis, the mean ICCs of symmetrized percent change improved in images processed with the denoising system (0.202/0.349/0.431) compared with the unprocessed images (0.167/0.325/0.404). In addition, the detectability of significant cortical thickness atrophy improved with denoising.

Conclusion: We confirm that the AI-based denoising system could effectively reduce the noise while retaining the contrast. We also confirm the improvement of the reliability and detectability of brain morphometric analysis with the denoising system.

El texto completo de este artículo está disponible en PDF.

Graphical Abstract




Image, graphical abstract

El texto completo de este artículo está disponible en PDF.

Keywords : Cortical thickness, Denoising, FreeSurfer, Magnetic resonance imaging, Morphometry, Surface-based morphometry

Abbreviations : FWHM, iQMR, ICC


Esquema


© 2021  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.