Suscribirse

Immediate, non-submerged, three-dimensionally printed, one-piece mandibular molar porous root-analogue titanium implants: A 2-year prospective study involving 18 patients - 31/05/22

Doi : 10.1016/j.jormas.2022.05.019 
Changkui Liu a, 1, Shuo Huang a, 1, Fang Guo a, Yongfeng Li b, Bingjing Zhao c, Aimin Luo d, Huawei Liu b, Chao Wang e, Min Hu b, Hongzhi Zhou f,
a Department of Stomatology, Xi'an Medical University, Xi'an, Shaanxi, 710021, China 
b Department of Stomatology, Chinese PLA General Hospital, Beijing, 100000, China 
c Department of stomatology, Air Force Medical Center, Beijing, 100000, China 
d Beijing ZhongAnTaiHua Technology Co., Ltd., Beijing, 100000, China 
e College of Stomatology, Chongqing Medical University, Chongqing, 401147, China 
f School of Stomatology, Air Force Medical University, Xi'an, Shaanxi, 710032, China 

Corresponding author at: School of Stomatology, Air Force Medical University, No. 145West Changle Road, Xi'an, 710032, ChinaSchool of StomatologyAir Force Medical UniversityNo. 145West Changle RoadXi'an710032China
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Tuesday 31 May 2022
This article has been published in an issue click here to access

Abstract

This study prospectively evaluated non-submerged, three-dimensionally printed, one-piece molar porous root-analogue titanium implants. A total of 18 non-restorable multiple-rooted teeth in 18 patients, aged 22–64 years, were included in this study. A series of computed tomography images of the mandible were selected and rendered into a digital model. The non-restorable mandibular molars were digitally separated from the surrounding alveolar bone, and served as the template on which the porous root-analogue titanium implants (RAIs) were designed with computer-aided design (CAD) software. The porous molar RAIs were fabricated with the selective laser melting technique (average particle size 20 μm) and inserted into the alveolar sockets after extraction of the non-restorable molars. Definitive restorations were placed after 3 months of uninterrupted healing. Peri-implant clinical and radiographic measurements were obtained 2 years later. All patients functioned well following 2 years of functional loading, and peri-implant clinical and radiographic measurements demonstrated implant stability. No implants were lost at the 2-year follow-up, and the survival rate was 100%. Three-dimensionally printed one-piece molar porous RAIs may be a promising option for the replacement of non-restorable molars that are planned for extraction. Additional studies are required to evaluate the long-term survival of implants fabricated using this technique.

El texto completo de este artículo está disponible en PDF.

Keywords : Custom-made, Immediate implants, Porous root-analogue implant, Primary stability, Selective laser melting


Esquema


© 2022  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.