Suscribirse

Fixation screw minimizes bone graft loss following autogenous lateral block graft augmentation: An experimental in vivo study - 23/08/22

Doi : 10.1016/j.jormas.2021.09.003 
Erick Ricardo Silva a, Liat Chaushu b, 1, , Vitor Ferreira Balan a, Daniele Botticelli c, Samuel Porfírio Xavier a
a Department of Oral and Maxillofacial Surgery and Periodontology, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil 
b Department of Periodontology and Implant Dentistry, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel 
c ARDEC Academy, Rimini, Italy 

Corresponding author at: Attending, Department of Periodontology and Implant Dentustry, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.AttendingDepartment of Periodontology and Implant DentustryThe Maurice and Gabriela Goldschleger School of Dental MedicineTel Aviv UniversityTel AvivIsrael

Abstract

Purpose

Assess the role of tenting screws in the remodeling processes of autogenous bone blocks used for mandibular lateral augmentation in rabbits.

Methods

Eighteen rabbits, approximately 3.5–4.0 kg of weight and 4–5 months of age, were included in this study. One lateral side of the angle of the mandible was augmented with block autografts. Animals were euthanized after 7, 20 and 60 days of healing, respectively. Biopsies were taken for each period and specimens underwent microtomographic scanning. The total volume (TV, mm3), bone volume (BV: residual graft plus new bone, mm3), periimplant bone volume (PIBV), bone implant contact (BIC) along the screw and linear bone gain at five vertical points symmetrically dispersed from the fixation screw in the midline were measured. ANOVA and the t-test were performed.

Results

The total volume (TV) of autografts decreased between 7 and 60 days from 258.13±15.3 mm3 to 107.2 ± 17.5 mm3 (p < 0.05). Contraction rates of 58.5% were observed. BV was 52.8 ± 7.7 mm3, 27.2 ± 11.1 mm3, and 33.1 ± 2.8 mm3 after 7, 20, and 60 days of healing, respectively. PIBV and BIC remained unchanged along time demonstrating no contraction around the screw. Total linear bone gain demonstrated a total of 18% linear contraction after 60 days. Point 1, demonstrated no changes along time representing no resorption along time. Points 2 and 4 demonstrate a minimum linear contraction (10–15%) with borderline significance. Resembling the total results, contraction starts after 20 days. Points 3 and 5 demonstrate a statistically significant contraction (p<0.05) of 35–40% starting at 20 days.

Conclusion

Tenting screws may reduce bone resorption symmetrically in a model of lateral block augmentation.

El texto completo de este artículo está disponible en PDF.

Key Words : Microtomography, Autograft, Rabbits


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 123 - N° 4

P. 395-400 - septembre 2022 Regresar al número
Artículo precedente Artículo precedente
  • Accuracy of digitally planned, guided apicoectomy with a conventional trephine and a custom-made endodontic trephine: An in vitro comparative study
  • Eszter Nagy, Gábor Braunitzer, Dániel Gerhard Gryschka, Ibrahim Barrak, Mark Adam Antal
| Artículo siguiente Artículo siguiente
  • Referencing for intraoperative navigation: Evaluation of human bias
  • Fabian Matthias Eckstein, Alexander-Nicolaj Zeller, Michael-Tobias Neuhaus, Philippe Korn, Nils-Claudius Gellrich, Rüdiger M. Zimmerer, Björn Rahlf

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.