Suscribirse

A Novel Method to Optimize Personal IOL Constants - 09/12/24

Doi : 10.1016/j.ajo.2024.08.029 
DANTE BUONSANTI 1, , DAVID L. COOKE 2, KENNETH J. HOFFER 3, 4, GIACOMO SAVINI 5, ENRICO LUPARDI 6, JORGE BUONSANTI 1, JAIME ARAMBERRI 7
1 From the Centro Buonsanti (D.B., J.B.), Buenos Aires, Argentina 
2 Great Lakes Eye Care (D.L.C.), Saint Joseph, Michigan, USA 
3 Stein Eye Institute, University of California (K.J.H.), Los Angeles, California, USA 
4 St. Mary's Eye Center (K.J.H.), Santa Monica, California, USA 
5 G.B. Bietti Foundation I.R.C.C.S. (G.S.), Rome, Italy 
6 Ophthalmology Unit, IRCSS Azienda Ospedaliero-Universitaria di Bologna (E.L.), Bologna, Italy 
7 Ophthalmology Clinic Miranza Begitek (J.A.), San Sebastian, Spain 

Inquiries to Dante Buonsanti, Centro Buonsanti, Larrea 1332, Buenos Aires, 1117, ArgentinaCentro BuonsantiLarrea 1332Buenos Aires1117Argentina

Resumen

Objective

To describe a novel method called “three variable optimization” that entails a process of doing just one calculation to zero out the mean prediction error of an entire dataset (regardless of size), using only 3 variables: (1) the constant used, (2) the average intraocular lens (IOL) power, and (3) the average prediction error (PE as actual refraction - predicted refraction).

Design

Development, evaluation, and testing of a method to optimize personal IOL constants.

Methods

A dataset of 876 eyes was used as a training set, and another dataset of 1,079 eyes was used to test the method. The Barrett Universal II, Cooke K6, Haigis, RBF 3.0, Hoffer Q, Holladay 1, Holladay 2, SRK/T, and T2 were analyzed. The same dataset was also divided into 3 subgroups (short, medium, and long eyes). The three variable optimization process was applied to each dataset and subset, and the obtained optimized constants were then used to obtain the mean PE of each dataset. We then compared those results with those obtained by zeroing out the mean PE in the classical method.

Results

The three variable optimization showed similar results to classical optimization with less data needed to optimize and no clinically significant difference. Dividing the dataset into subsets of short, medium and long eyes, also shows that the method is useful even in those situations. Finally, the method was tested in multiple formulas and it was able to reduce the PE with no clinically significant difference from classical optimization.

Conclusion

This method could then be applied by surgeons to optimize their constants by reducing the mean prediction error to zero without prior technical knowledge and it is available online for free at wwww.ioloptimization.com.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supplemental Material available at AJO.com.


© 2024  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 269

P. 355-361 - janvier 2025 Regresar al número
Artículo precedente Artículo precedente
  • Does the Visual Field Improve After Initiation of Intraocular Pressure Lowering in the United Kingdom Glaucoma Treatment Study?
  • Peter F. Reddingius, Stephen R. Kelly, Giovanni Ometto, David F. Garway-Heath, David P. Crabb, United Kingdom Glaucoma Treatment Investigators
| Artículo siguiente Artículo siguiente
  • Multifocal Vitelliform Paravascular Retinopathy (MVPR): A New Disorder in the Vitelliform Spectrum
  • Weilin Song, Sandeep Randhawa, Mark W. Johnson, Marcela Bohn, Anita Agarwal, Ehsan Rahimy, Kenneth J. Taubenslag, Peter Charbel Issa, Omar A. Mahroo, Jacques Bijon, H. Richard McDonald, Scott D. Walter, Yoshihiro Yonekawa, SriniVas Sadda, K. Bailey Freund, David Sarraf

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.