Fully automated deep learning-based pipeline for Evans Index measurement from raw 3D MRI - 24/03/26

Doi : 10.1016/j.neuri.2026.100275 
Siavash Shirzadeh Barough a , Murat Bilgel b , Ameya Moghekar a , Catalina Ventura a , Marilyn S. Albert a , Mark G. Luciano c , Abhay Moghekar a,
a Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, 21224, USA 
b Laboratory of Behavioral Neuroscience, National Institute on Aging, NIH, Baltimore, MD, 21224, USA 
c Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA 

Corresponding author. Department of Neurology, Johns Hopkins University School of Medicine, Suite 5100, 5200 Eastern Ave, Baltimore, MD, 21224, USA. Department of Neurology Johns Hopkins University School of Medicine Suite 5100 5200 Eastern Ave Baltimore MD 21224 USA

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Ventriculomegaly is a key neuroimaging feature of normal pressure hydrocephalus (NPH) and other disorders of cerebrospinal fluid (CSF) dynamics. The Evans Index (EI), defined as the ratio of maximal frontal horn width to maximal inner skull diameter, is a widely used marker of ventricular enlargement. However, manual EI measurement is susceptible to inter-observer variability and depends on accurate alignment to the anterior commissure-posterior commissure (AC-PC) plane, limiting reproducibility in large and multi-center studies.

We developed a fully automated deep learning–based pipeline for EI calculation directly from raw T1-weighted MPRAGE MRI scans. The pipeline integrates automated landmark detection using the BrainSignsNet model, rigid AC-PC alignment for orientation standardization, and robust segmentation of the lateral ventricles (LV) and intracranial volume (ICV) using nnU-Net models. Ventricular segmentation is performed with a custom network trained on 1300 manually annotated scans enriched for hydrocephalus. The Evans Index is then derived automatically from frontal horn width and inner skull diameter measured on the aligned axial slice.

Internal validation across the Baltimore Longitudinal Study of Aging, BIOCARD, and Johns Hopkins cohorts demonstrated excellent segmentation performance (Dice coefficient = 0.98). External validation in the PENS trial, including pre- and post-shunt NPH scans, showed strong agreement with expert manual EI measurements (mean bias = 0.0068, mean absolute error = 0.0103, r = 0.96, p < 0.001), with no bias related to age, sex, or ventricular volume.

This automated, orientation-standardized approach enables accurate, reproducible, and scalable Evans Index assessment for clinical and research applications, particularly in NPH.

El texto completo de este artículo está disponible en PDF.

Graphical abstract




Image 1

El texto completo de este artículo está disponible en PDF.

Highlights

Automated deep learning pipeline calculates Evans Index directly from raw 3D MRI.
Internal and external validation show excellent agreement with expert manual measures.
Automated AC-PC alignment ensures reproducibility across varying head orientations.
Method shows no significant bias regarding age, sex, or ventricular volume.

El texto completo de este artículo está disponible en PDF.

Keywords : Evans Index, Normal pressure hydrocephalus, Deep learning, Magnetic resonance imaging


Esquema


© 2026  The Authors. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 6 - N° 2

Artículo 100275- juin 2026 Regresar al número
Artículo precedente Artículo precedente
  • Machine learning for preoperative predictions in Vestibular Schwannoma: A systematic review
  • Pasan Kalansooriya, Sudanthi Wijewickrema, Sevvandi Kandanaarachchi, Bridget Copson, Jean-Marc Gerard, Stephen O’leary
| Artículo siguiente Artículo siguiente
  • Histogram-Derived MREPT connectome: A distribution-Aware framework for brain network analysis
  • Geon-Ho Jahng, Mun Bae Lee, Oh-In Kwon

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.