Suscribirse

Les conservateurs des collyres : vers une prise de conscience de leur toxicité - 27/09/10

Doi : 10.1016/j.jfo.2010.06.018 
D. Vaede a, C. Baudouin b, c, , d , J.-M. Warnet a, b, F. Brignole-Baudouin a, b
a Laboratoire de toxicologie, faculté des sciences pharmaceutiques et biologiques, université Paris Descartes, 75006 Paris, France 
b Inserm, U968, UPMC université Paris 06, UMR S 968, institut de la vision, CNRS, UMR 7210, 75012 Paris, France 
c Service ophtalmologie III, centre hospitalier national d’ophtalmologie des Quinze-Vingts, 28, rue de Charenton, 75012 Paris, France 
d Université de Versailles St-Quentin, hôpital Ambroise-Paré, AP–HP, 9, avenue Charles-de-Gaulle, 92100 Boulogne, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Résumé

Les conservateurs sont présents dans de nombreux collyres multidoses. Ils assurent la stérilité de la solution vis-à-vis des bactéries et champignons. Cependant, des études ont montré que les conservateurs sont toxiques pour la surface oculaire notamment chez les patients prenant des collyres au long cours. Le conservateur le plus employé dans les collyres est le chlorure de benzalkonium, ammonium quaternaire utilisé comme détergent, antiseptique, désinfectant, fongicide, bactéricide et spermicide. Son utilisation sur la surface oculaire pourrait avoir des conséquences importantes en particulier sur le long terme. En effet, les conservateurs provoquent la dissolution du film lacrymal et sont pro-apoptotiques et pro-inflammatoires. L’administration prolongée de collyres contenant un ou plusieurs conservateurs conduit à une altération des structures superficielles (conjonctive, cornée) et plus profondes (trabéculum, cristallin). Les signes et symptômes oculaires les moins sévères se manifestent par une gêne ou des irritations : sensation de corps étranger de picotement ou brûlure, d’œil sec. Pour les effets secondaires les plus graves, on observe une inflammation d’intensité variable allant d’une simple réaction infraclinique au développement progressif d’une fibrose avec entre autres un risque accru d’échec en cas de chirurgie du glaucome. Le meilleur moyen de limiter ces complications passe par la réduction du nombre d’instillations de collyres conservés, et idéalement par l’utilisation de collyres sans conservateur, chaque fois que cela est possible. Une meilleure prise en charge de la surface oculaire devrait permettre d’augmenter le confort du patient, l’observance du traitement et d’assurer l’efficacité d’une future chirurgie filtrante chez les patients atteints de glaucome.

El texto completo de este artículo está disponible en PDF.

Summary

Preservatives are present in numerous multidose eyedrops and provide the sterility of the solution against bacteria and fungi. However, numerous studies have shown their toxicity for the ocular surface, particularly in long-term treatments. The most widely used preservative in eyedrops is benzalkonium chloride. This quaternary ammonium acts as a detergent, antiseptic, disinfectant, fungicide, bactericide, and spermicide. Its use on the ocular surface therefore has significant consequences. Indeed, the preservatives are pro-apoptotic, pro-inflammatory and they cause the dissolution of the lachrymal film. The prolonged administration of one or several eye drops containing preservatives induces changes in the superficial structures (conjunctiva, cornea) as well as in deeper structures (trabecula, lens). The least severe symptoms are irritation and discomfort, including sensation of a foreign body, itching, or burning sensations. However, more severe side effects have been described, such as chronic inflammation of variable intensity or the progressive development of fibrosis with higher risk of failure after glaucoma filtering surgery. Ideally, preservative-free eyedrops should be recommended, or at least a reduction of the number of instilled preserved eyedrops should be considered. All these strategies could increase patient comfort, quality of life, and compliance, with better outcome at the time of filtering surgery.

El texto completo de este artículo está disponible en PDF.

Mots clés : Glaucome, Collyres, Conservateurs, Benzalkonium, Toxicité, Surface oculaire

Keywords : Glaucoma, Eyedrops, Preservatives, Benzalkonium, Toxicity, Ocular surface


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 33 - N° 7

P. 505-524 - septembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Traitement des hémangiomes choroïdiens circonscrits par photothérapie dynamique : revue de la littérature
  • J. Gambrelle, C. Graswill, M. Mauget-Faysse, L. Kodjikian, B. Cochener, J.-D. Grange
| Artículo siguiente Artículo siguiente
  • Cataracte sous-capsulaire postérieure sur corps étranger intracristallinien
  • L. Pinsard, F. Thoumazet, B. Mortemousque, J.-F. Korobelnik, J. Colin, M.-N. Delyfer

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.