Suscribirse

Total knee arthroplasty for osteoarthritis secondary to extra-articular malunions - 30/11/10

Doi : 10.1016/j.otsr.2010.06.010 
G. Deschamps a, F. Khiami b, Y. Catonné b, C. Chol a, C. Bussière a, P. Massin c,

The French Hip and Knee Society (S.F.H.G.)1

  56, rue Boissonade, 75014 Paris, France.

a Medico-Surgical Hospital Center, 2, rue du Pressoir, 71640 Dracy-le-Fort, France 
b Orthopaedic Surgery Department, La Pitié Salpêtrière Hospital, Pierre-et-Marie-Curie University, 47-83, boulevard de l’Hôpital, 75651 Paris cedex 13, France 
c Orthopaedic Surgery and Traumatology Department, Bichat Claude-Bernard Teaching Medical Center, Paris Diderot University, 46, rue Henri-Huchard, 75877 Paris cedex 18, France 

Corresponding author. Tel.: +(33) 1 40 25 75 03.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Post-traumatic total knee arthroplasty for extra-articular malunion requires correction of the deformity, either through asymmetrical bone resection (possibly inducing ligaments imbalance) or osteotomy at the time of arthroplasty. We report the results of a continuous multicenter, retrospective series of 78 patients (18 implants with osteotomy) with a mean 4 years of follow-up. The hypothesis is that the selected procedure requires to be based on the deformity’s location and severity.

Patients

With a mean age of 63 years (younger in the osteotomy group), 38 patients had femoral malunion, 36 had tibial malunion, and four had a combined malunion. There were 70 frontal deformities (48 varus and 22 valgus) and 10 rotational deformities, often diaphyseal, four of which more than 20°. Twelve patients had a history of infection; eight had frontal laxity greater than 10°, and 15 a limited range of motion in flexion. In 70 cases, semi- or nonconstrained implants were used, and in eight cases more constrained implants, including four hinge prostheses.

Results

We observed two deep infections, one case of avulsion of the extensor mechanism, and two cases of aseptic loosening with femoral malunion and varus deformity. Two osteotomies resulted in nonunion, one with internal fixation devices mobilization requiring revision using extension rods. The function and pain scores were significantly improved. The mobility improvements were moderate but did not compromise the surgical procedure main objective. The preoperative hip-knee angle was corrected with both techniques. Only the function score gain was greater for the isolated arthroplasty procedures.

Discussion and conclusion

The indications for arthroplasty alone were extended to 20° varus and 15° valgus, with no major residual laxity. Beyond 10°, hinge prosthesis should be available. Associated osteotomy can correct rotational deformities that cannot be compensated with bone cuts. In deformities that are close to the joint, osteotomy facilitates implantation of moderately constrained prosthesis. This indication is based on CAT scan rotational deformities measurements because rotational deformities require an osteotomy, and/or the presence of extraligamentous deformity that cannot be reduced with collateral ligaments surgical release.

Level of evidence

Level 4. Non-controlled retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Extra-articular malunion, Total knee prosthesis, Traumatic knee arthritis


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 96 - N° 8

P. 849-855 - décembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • CT evaluation of torsional malalignment after intertrochanteric fracture fixation
  • M. Ramanoudjame, P. Guillon, C. Dauzac, C. Meunier, J.M. Carcopino
| Artículo siguiente Artículo siguiente
  • Post-traumatic knee osteoarthritis treated by osteotomy only
  • S. Lustig, F. Khiami, P. Boyer, Y. Catonne, G. Deschamps, P. Massin, The French Hip and Knee Society e

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.